Laserfiche WebLink
Electronic Submittal Information <br />' Main Menu I V1eW/A6d Facihttes I Upload EDD I Check EDD <br /> Your EDF file has been successfully uploadedt <br />' Confirmation Number: 9959409594 <br /> Date/Time of Submittal: 11/22/2005 11 22 21 AM <br />' Facility Global ID: 70607700323 <br /> Facility Name: DSS COMPANY <br />' Submittal Title: 09-22-2005 CPT <br /> Submittal Type: Soil &Water Investigation Report <br /> Click here to view the detections report for this upload <br /> DSS COMPANY Regional Board-Case#:390415 <br />' 639 CLAY ST W CENTRAL VALLEY RWQCB(REGION 5S)-(JLB) <br /> STOCKTON, CA 95206 Local Aeency_(lead agency)-Case# 1065 <br /> SAN JOAQUIN COUNTY LOP-(JEF) <br />' <br /> CON" TITLE QUARTER <br /> 9959409594 09-22-2005 CPT Q3 2005 <br /> SUBMITTED BY SUBMIT DATE STATUS <br /> Christopher Miller 11/22/2005 PENDING REVIEW <br />' SAMPLE DETECTIONS REPORT <br /> # FIELD POINTS SAMPLED 1 <br />' # FIELD POINTS WITH DETECTIONS 0 <br /> # FIELD POINTS WITH WATER SAMPLE DETECTIONS ABOVE MCL 0 <br /> SAMPLE MATRIX TYPES WATER <br />' METHOD -OA/QC REPORT <br /> METHODS USED 8260+OX,8260FAB,M801S <br /> TESTED FOR REQUIRED ANALYTES> N <br /> MISSING PARAMETERS NOT TESTED <br />' - 8260+OX REQUIRES ACE TO BE TESTED <br /> - 8260+OX REQUIRES ACCN TO BE TESTED <br /> - 8260+OX REQUIRES ACRL TO BE TESTED <br /> - 8260+OX REQUIRES ACRAMD TO BE TESTED <br /> - 8260+OX REQUIRES CLPE3 TO BE TESTED <br /> - 8260+OX REQUIRES BZLCL TO BE TESTED <br /> - 8260+OX REQUIRES B2CES TO BE TESTED <br /> - 8260+OX REQUIRES BALE TO BE TESTED <br /> - 8260+OX REQUIRES BRCLME TO BE TESTED <br /> - 8260+OX REQUIRES BDCME TO BE TESTED <br /> - 8260+OX REQUIRES TBME TO BE TESTED <br /> - 8260+OX REQUIRES BRME TO BE TESTED <br />' - 8260+OX REQUIRES BTOH TO BE TESTED <br /> - 8260+OX REQUIRES MEK TO BE TESTED <br /> - 8260+OX REQUIRES CDS TO BE TESTED <br /> - 8260+OX REQUIRES CTCL TO BE TESTED <br /> - 8260+OX REQUIRES CHLORALHY TO BE TESTED <br /> - 8260+OX REQUIRES CLBZD5 TO BE TESTED <br /> - 8260+OX REQUIRES DBCME TO BE TESTED <br /> - 8260+OX REQUIRES CLEA TO BE TESTED <br /> - 8260+OX REQUIRES CEVETH TO BE TESTED <br /> - 8260+OX REQUIRES TCLME TO BE TESTED <br /> - 8260+OX REQUIRES CLME TO BE TESTED <br /> - 8260+OX REQUIRES CHLOROPRENE TO BE TESTED <br /> - 8260+OX REQUIRES CPN3 TO BE TESTED <br /> - 8260+OX REQUIRES 2BUTENAL TO BE TESTED <br />' - 8260+OX REQUIRES DBCP TO BE TESTED <br /> - 8260+OX REQUIRES DBMA TO BE TESTED <br /> - 8260+OX REQUIRES DCBZ12 TO BE TESTED <br /> - 8260+OX REQUIRES DCBZ13 TO BE TESTED <br /> - 8260+OX REQUIRES DCBZ14 TO BE TESTED <br />