Laserfiche WebLink
r 110 211d Avenue South #D7 Pacheco CA 94553 5560 <br /> McCampbell Analytical, Inc. Telephone 925 798-1620 Fax 925 798 1622 <br /> Website www mccampbell coni E mail niain@mccampbell cam <br /> QC SUMMARY REPORT FOR 6020A <br /> W O Sample Matrix Soil QC Matrix Soil WorkOrder 0504049 <br /> EPA Method 6020A Extraction SW3050B BatchlD 15745 Spiked Sample ID 0504052-017A <br /> Sample Spiked MS MSD MS-MSD Spiked LCS. LCSD LCS-LCSD Acceptance Criteria(%) <br /> Analyte <br /> mg/Kg mg/Kg % Rec % Rec %RPD mg/Kg % Rec % Rec % RPD MS 1 MSO LCS/LCSD <br /> Aluminum 8100 5000 NR NR NR 5000 956 972 1 66 75 125 80- 120 <br /> Calcium 4900 5000 106 109 1 66 5000 94 8 952 0 400 75- 125 80-120 <br /> It on 17,000 500 NR NR NR 500 95 5 95 9 0 502 75- 125 1 SO- 120 <br /> Magnesium 3800 500 NR NR NR 500 962 975 1 32 75- 125 80-1-120 <br /> Manganese 190 500 105 Ito 3 65 500 967 982 1 52� 75- 125 80- 120 <br /> Potassium 770 500 NR NR NR 500 962 974 1 24 75- 125 1 80-120 <br /> Sodium 420 5000 983 I 101 261 5000 97 1 967 0 310 75- 125 80 120 <br /> %SS 113 1 250 114 116 1 28 250 104 104 D 80- 120 80-120 <br /> All target compounds in the Method Blank of this extraction batch were ND less than the method RL with the following exceptions <br /> NONF <br /> BATCH 15745 SUMMARY <br /> ample ID Date Sampled Date Extracted Date Analyzed Sample ID Date Sampled Date Extracted Date Analyzed <br /> 0504049-001 A 4/01/05 4105105 4107105 9 15 AM 0504049-OOIA 4101105 4105105 4/07/05 9 24 AM <br /> 0504049-001 A 4/01105 4105/05 4109/05 3 48 AM 0504049-OOIA 4/01105 4/05105 4/18/05 1 09 PM <br /> 0504049-008A 4101105 4105105 4113/05 11 18 AM 0504049-008A 4101105 4/05/05 4/13/05 l 127 AM <br /> 0504049 008A 4101/05 4105/05 4/13/05 7 22 PM 0504049-O08A 4/01105 4/05/05 4114/05 l 58 PM <br /> MS=Matrix Spike MSD=Matrix Spike Duplicate LCS=Laboratory Control Sample LCSD=Laboratory Control Sample Duplicate RPD=Relative Percent Deviation <br /> %Recovery=100'(MS-Sample)I(Amount Spiked) RPD= 100'(MS- MSD)I((MS+MSD)12) <br /> MS 1 MSD spike recoveries and 1 or%RPD may fall outside of laboratory acceptance criteria due to one or more of the following reasons a)the sample is inhomogenous AND <br /> contains significant concentrations of analyte relative to the amount spiked or b)the spiked sample's matrix interferes with the spike recovery <br /> NIA=not applicable to this method <br /> N R=analvte concentration in sample exceeds spike amount for sod matnx or exceeds 2x spike amount for water matrix or sample diluted due to high matnx or analyte content <br /> OPHS Certification.No 1644 C-, QA/QC Officer <br />