Laserfiche WebLink
i <br /> ' k'" KLEINFE [ DER <br /> ' A-2.5 Collection of BAT Probe Groundwater S_ triples <br /> One-time groundwater samples are collected using a BAT Probe, which is an msitu groundwater <br /> ' <br /> sampling device The bonn s are first advanced to a point immediate) above the desired <br /> p g g p Y <br /> sampling depth where groundwater is encountered A stainless steel drive tip equipped with a <br /> ' stainless steel filter is lowered into the boring at the end of a 2 5-inch diameter galvanized steel <br /> pipe and pushed using the drill ng approximately 6 to 12 inches into the soil/aquifer formation at <br /> ' the bottom of the boring A sterilized, glass, vacuum sealed sampling ampoule (tube), similar to <br /> a standard volatile organics (VOA) vial, is then lowered through the pipe down to the tip with a <br /> ' cable Between the tip and the sample tube is a double-sided hypodermic needle (syringe), <br /> which simultaneously punctures the seals on the stainless steel dnve tip and the septum of the <br /> ' glass sample ampoule The vacuum in the sample ampoule draws groundwater through the tip <br /> into the glass ampoule The glass ampoule is then pulled out of the pipe, disengaging the <br /> ' syringe The septum in the glass ampoule and drive tip reseals after the syringe is removed <br /> To reduce the potential for introducing contaminants into the samples, the drive tip, galvanized <br /> pipe, and other equipment used for sample collection are steam cleaned and/or washed with <br /> trisodium phosphate or non-phosphate detergent solution and double rinsed with distilled water <br /> ' prior to use The sample probe and filters are cleaned in TSP solution and rinsed with methyl <br /> alcohol followed by a distilled water rinse pnor to use New, factory-sten lized synnge needles, <br /> 0-rings, septums and sample tubes are used for each sample <br /> ' A-2.6 Sample Handling <br /> ' After labeling, the sample is immediately stored in an iced cooler for transport to Kleinfelder's <br /> office sample control or to the analytical laboratory A Kleinfelder chain-of-custody form <br /> ' accompanies the cooler The chain-of-custody form includes Kleinfelder's name, address and <br /> telephone number, the employee number of the individual who performed the sampling, the <br /> ' sample numbers, the date and time the samples were collected, the number of containers each <br /> sample occupies, the sample matrix (soil or water) and the analyses for which the samples are <br /> being submitted, if any The chain-of-custody form is signed by each person who handles the <br /> ' samples, including all Kleinfelder employees and the receiving employee of office sample <br /> • control or the analytical laboratory when the samples are delivered <br /> 28699 E01 /ST03R627 Page A-3 <br /> ' Copyngll 2003,Klemfelder,Inc Apn122,2003 <br />