My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS XR0001016
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
COUNTRY CLUB
>
1267
>
2900 - Site Mitigation Program
>
PR0505602
>
ARCHIVED REPORTS XR0001016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/20/2019 2:44:56 PM
Creation date
6/20/2019 1:45:44 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0001016
RECORD_ID
PR0505602
PE
2950
FACILITY_ID
FA0006891
FACILITY_NAME
BANK OF THE WEST
STREET_NUMBER
1267
STREET_NAME
COUNTRY CLUB
STREET_TYPE
BLVD
City
STOCKTON
Zip
95204
APN
11304217
CURRENT_STATUS
02
SITE_LOCATION
1267 COUNTRY CLUB BLVD
P_LOCATION
01
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
C A B R A Mr Michael Infurna <br /> • June 22, 2005 <br /> 51 fbg in CPT-1 and at 2 0 ppm at 52 fbg in CPT-2 Therefore, CPT-1 and CPT-2 also delineated <br /> TPHd in soil above 60 and 58 fbg, respectively Soil samples collected from well boring S-2 <br /> contained TPHg concentrations of 28 ppm at 25 fbg and 570 ppm at 30 fbg TPHg was not <br /> detected in soil collected from the other well borings No benzene or fuel oxygenates (by EPA <br /> Method 8260) were detected in soil from any of the well borings Cambria's July 14, 1998 Site <br /> Investigation Report documented these activities <br /> 2003 Site Investigation During August 2003, Cambria advanced five CPT borings (CPT-3 <br /> through CPT-7) Shallow soil samples (from 5 to 15 fbg) from the borings were analyzed for <br /> TPHd The 5-fbg samples from borings CPT-3, CPT-4, and CPT-7 contained 1 2 to 11 ppm <br /> TPHd TPHd was not detected in deeper samples, and the laboratory noted that the hydrocarbon <br /> patterns did not match the diesel standard and were unidentifiable <br /> Groundwater samples were collected from all the borings in primarily sandy zones TPHd was <br /> detected in groundwater samples from all the borings at concentrations ranging from 53 to <br /> 680 ppb The laboratory noted that none of the hydrocarbons reported as TPHd matched the <br /> laboratory's diesel standard Upon further review, the laboratory determined that the <br /> hydrocarbons were aged gasoline TPHg was also detected in groundwater samples from all the <br /> borings at concentrations ranging from 79 to 2,000 ppb The laboratory noted that some of the <br /> . hydrocarbons reported as TPHg did not match the laboratory's gasoline standard and were due to <br /> the presence of aged gasoline Benzene was detected in groundwater samples from borings <br /> CPT-4 and CPT-6 at concentrations ranging from 1 6 to 21 ppb 1,2-DCA was detected in the <br /> sample collected in boring CPT-6 at 85 fbg at 0 64 ppb Cambria's February 27, 2004 Site <br /> Investigation Report summarized this investigation <br /> Groundwater Monitoring Program There are four monitoring wells on site (S-1 through S-4) <br /> and two off-site monitoring wells (S-5 and S-6), located north of the site in Elmwood Avenue <br /> Wells S-1 through S-4 are sampled quarterly, and wells S-5 and S-6 are sampled annually dunng <br /> the first quarter During the first quarter 2005 sampling event, TPHd was detected in wells S-1, <br /> S-2, and S-3 at concentrations ranging from 150 to 2,700 ppb, however, the laboratory noted that <br /> the hydrocarbon reported was in the early diesel range and did not match the standard for diesel <br /> TPHg was also detected in wells S-1, S-2, and S-3 at concentrations ranging from 140 to <br /> 15,000 ppb Benzene was detected in wells S-1 and S-3 at 300 and 6 2 ppb, respectively Well <br /> S-3 contained 9 8 ppb 1,2-DCA No petroleum hydrocarbons or 1,2-DCA were detected in wells <br /> S-4, S-5, and S-6 <br /> SITE INVESTIGATION WORK PLAN ADDENDUM <br /> Permit Cambria will obtain an appropriate drilling permit from SJCEHD <br /> 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.