Laserfiche WebLink
CAMBRIA <br /> ethylbenzene, xylenes (BTEX), or fuel oxygenates were detected in soil from these borings <br /> Therefore., these bonngs delineate these constituents in soil above 40 fbg TPHd was detected at <br /> 16 ppm at 51 fbg in CPT-1 and at 2 0 ppm at 52 fbg in CPT-2 Therefore, CPT-1 and CPT-2 <br /> also delineate TPHd in soil above 60 and 58 fbg, respectively Soil samples collected from well <br /> boring S-2 contained TPHg concentrations of 28 ppm at 25 fbg and 570 ppm at 30 fbg TPHg <br /> was not detected in soil collected from the other well bonngs No benzene or fuel oxygenates <br /> (by EPA Method 8260) were detected in soil from any of the well bonngs These activities are <br /> documented in Cambria's July 14, 1998 Site Investigation Report <br /> 2003 Site Investigation During August 2003, Cambria drilled five CPT borings (CPT-3 through <br /> CPT-7) Shallow soil samples (from 5 to 15 fbg) from the borings were analyzed for TPHd The <br /> 5-fbg samples from bonngs CPT-3, CPT-4, and CPT-7 contained 12 to 11 ppm TPHd TPHd <br /> was not detected in deeper samples, and the laboratory noted that the hydrocarbon patterns did <br /> not match the diesel standard and were unidentifiable <br /> Groundwater samples were collected from all the borings in primarily sandy zones TPHd was <br /> detected in groundwater samples from all the borings at concentrations ranging from 53 to <br /> 680 ppb The laboratory noted that none of the hydrocarbons reported as TPHd matched the <br /> laboratory's diesel standard Upon further review, the laboratory determined that the <br /> hydrocarbons were aged gasoline TPHg was also detected in groundwater samples from all the <br /> borings at concentrations ranging from 79 to 2,000 ppb The laboratory noted that some of the <br /> hydrocarbons reported as TPHg did not match the laboratory's gasoline standard and were due to <br /> the presence of aged gasoline Benzene was detected in groundwater samples from borings <br /> CPT-4 and CPT-6 at concentrations ranging from 16 to 21 ppb 1,2-DCA was detected in the <br /> sample collected in boring CPT-6 at 85 fbg at 0 64 ppb Cambria summarizes this investigation <br /> in our February 27, 2004 Site Investigation Report <br /> Groundwater Monitoring Program• There are currently four monitoring wells onsite (S-1 <br /> through S-4) and two offsite monitoring wells (S-5 and S-6), located north of the subject site in <br /> Elmwood Avenue Currently wells S-1 through S-4 are monitored and sampled quarterly and <br /> wells S-5 and S-6 are monitored and sampled annually During the fourth quarter 2003 sampling <br /> event, TPHd was detected in wells S-1 through S-3 at concentrations ranging from 180 to <br /> 980 ppb, however, the pattern generated by these samples do not match the laboratory's standard <br /> for diesel TPHg was also detected in wells S-1 through S-3 at concentrations ranging from 130 <br /> to 12,000 ppb, however, the sample collected from well S-3 did not match the laboratory's <br /> standard for gasoline Benzene was detected in wells S-1 and S-3 at 120 and 41 ppb, <br /> i <br /> 0943 3 <br />