Laserfiche WebLink
BP #11192 (FORMER�IL) Page 1 of 1 <br /> LTCP Checklist - Go GEOTRACKER HOME I MANAGE PROJECTS I REPORTS 15EffigH I LO UT <br /> BP#11192(FORMER MOBIL)(T0607700329)-MAP THIS SITE OPEN-REMEDIATION <br /> 1403 COUNTRY CLUB BLVD ACTIVITIES REPORT CLEANUP OVERSIGHT AGENCIES <br /> STOCKTON,CA 95204 SAN JOAQUIN COUNTY LOP(LEAD)-CASE#:1995123 <br /> SAN JOAQUIN COUNTY PUBLIC WEBPA CASEWORKER:LISA MEDINA - SUPERVISOR:ADRIENNE ELLSAESSER <br /> VIEW PRINTABLE CASE SUMMARY FOR THIS SITE CENTRAL VALLEY RWQCB(REGION 5S)-CASE#:390424 <br /> CASEWORKER:JAMES BARTON - SUPERVISOR:BRIAN NEWMAN <br /> CUF Claim#:2413 CUF Priority Assigned:D CUF Amount Paid:$183,394 <br /> THIS PROJECT WAS LAST MODIFIED BY LISA MEDINA ON 6/25120131:14:59 PM•Eja= <br /> THIS SITE HAS SUBMITTALS.CLICK HERE TO OPEN A NEW WINDOW WITH THE SUBMITTAL APPROVAL PAGE FOR THIS SITE. <br /> CLOSURE POLICY THIS VERSION IS IN PROGRESS AS OF 6/25/2013 CHECKLIST INITIATED ON 62&1013 CLOSURE POLICY HISTORY <br /> General Criteria-The site satisfies the policy general criteria-CLEAR SECTION ANSMRS EYEKl <br /> a.Is the unauthorized release located within the-service area of a public waters stem? <br /> Name of Water System: CalWater YES C NO <br /> b.The unauthorized release consists only of petroleum Lbfm. .r YES C NO <br /> c.The unauthorized('primary")release from the UST system has been stopped. � •("'YES C NO <br /> d.Free product has been removed to the maximum extent practicable info. 11- FP Not Encountered «r YES f- NO <br /> e.A conceptual site model that assesses the nature,extent,and mobility of the release has been developed info. ES C NO <br /> C Secondary source has been removed to the extent practicable JinfP1. C YES C NO <br /> g.Soil or groundwater has been tested for MTBE and results reported in accordance with Health and Safety Code Section <br /> 25296.15. C Not Required YES C NO <br /> h.Does a nuisance exist,as defined by Water Code section 13050. C YES NO <br /> 1.Media-Specific Criteria:Groundwater-The contaminant plume that exceeds water quality objectives is stable or <br /> decreasing in areal extent,and meets all of the additional characteristics of one of the five classes of sites listed below.-al FGR YES <br /> SECTION ANSWERS <br /> EXEMPTION-Soil Only Case(Release has not Affected Groundwater-Info) C YES ''NO <br /> Does the site meet any of the Groundwater specific criteria scenarios? 6 YES C NO <br /> v I 1.2-The contaminant plume that exceeds water quality objectives is<250 feet in length.There is no free product.The nearest existing water supply well or <br /> a surface water body is>1,000 feet from the defined plume boundary.The dissolved concentration of benzene is<3,000 Ng/L.The dissolved concentration of r YES C NO <br /> MTBE is<1,000 Ng/L. - J <br /> 2.Media Specific Criteria: Petroleum Vapor Intrusion to Indoor Air-The site is considered low-threat for the vapor- YES <br /> intrusion-to-air pathway if site-specific conditions satisfy items 2a, 2b,or 2c-CLEAR SECTION ANSWERS <br /> EXEMPTION-Active Commercial Petroleum Fueling Facility .f" YES C NO <br /> 3.Media Specific Criteria:Direct Contact and Outdoor Air Exposure-The site is considered low-threat for direct contact YES <br /> and outdoor air exposure if it meets 1,2,or 3 below.-CLEAR SECTION ANSWERS <br /> EXEMPTION-The upper 10 feet of soil is free of petroleum contamination R YES NO <br /> Additional Information <br /> This case should be kept OPEN in spite of meeting policy criteria. C YES C NO <br /> SPELL CHECK <br /> Save in Progress <br /> LOGGED IN AS MAMASITALISA CONTACT GEOTRACKER HELP <br /> �/1.t1 )� (' !!' �•Jr ,-:.r �1 ! J fir; � <br /> r- r <br /> i <br /> https:Hgeotracker.waterboards-ca.gov/regulators/screens/closure—policy.asp... 6/25/2013, <br />