Laserfiche WebLink
ANALYTICAL TECHNOLOGIES,INC. <br /> SAN DIEGO <br /> FLAGS <br /> ORGANICS <br /> FLAG MESSAGE DESCRIPTION <br /> A A TIC IS A SUSPECTED ALDOL-CONDENSATION PRODUCT <br /> B ANALYTE FOUND IN THE ASSOCIATED REAGENT BLANK <br /> C PESTICIDE, WHERE THE IDENTIFICATION WAS CONFIRMED BY GC/MS <br /> CO THESE COMPOUNDS CO-ELUTE AND ARE QUANTITATED AS ONE PEAK <br /> D COMPOUND IDENTIFIED IN AN ANALYSIS AT SECONDARY DILUTION <br /> E ANALYTE AMOUNT EXCEEDS THE CALIBRATION RANGE <br /> J ESTIMATED—VALUE <br /> H QUANTIFIED AS DIESEL BUT CHROMATOGRAPHIC PATTERN DOES NOT MATCH <br /> THAT OF DIESEL <br /> K QUANTIFIED AS KEROSENE BUT CHROMATOGRAPHIC PATTERN DOES NOT MATCH <br /> THAT OF KEROSENE <br /> L QUANTIFIED AS GASOLINE BUT CHROMATOGRAPHIC PATTERN DOES NOT MATCH <br /> THAT OF GASOLINE <br /> N PRESUMPTIVE EVIDENCE OF A COMPOUND <br /> P PESTICIDE/AROCLOR TARGET ANALYTE, WHERE THERE IS GREATER THAN 25% <br /> DIFFERENCE FOR DETECTED CONCENTRATION BETWEEN 2 GC COLUMNS <br /> TR COMPOUND DETECTED AT AN UNQUANTIFIABLE TRACE LEVEL <br /> U COMPOUND WAS ANALYZED FOR BUT NOT DETECTED <br /> X SEE CASE NARRATIVE <br /> Y SEE CASE NARRATIVE <br /> Z SEE CASE NARRATIVE <br /> * OUTSIDE OF QUALITY CONTROL LIMITS <br /> *D COMPOUND ANALYZED FROM A SECONDARY ANALYSIS <br /> *F RESULT OUTSIDE OF ATI'S QUALITY CONTROL LIMITS <br /> *G RESULT OUTSIDE QUALITY CONTROL LIMITS. INSUFFICIENT SAMPLE FOR RE- <br /> EXTRACTION/ANALYSIS <br /> *H RESULT OUTSIDE OF LIMITS DUE TO SAMPLE MATRIX INTERFERENCE <br /> *I BECAUSE OF NECESSARY SAMPLE DILUTION, VALUE WAS OUTSIDE QC LIMITS <br /> *K DUE TO THE NECESSARY DILUTION OF THE SAMPLE,RESULT WAS NOT ATTAINABLE <br /> *L ANALYTE IS A SUSPECTED LAB CONTAMINANT <br /> *P A STANDARD WASED TO QUANTITATE-THIS`'tIAI:UE <br /> S U <br /> *R DATA IS NOT USABLE <br /> *T SURROGATE RECOVERY IS OUTSIDE QC CONTROL LIMITS.NO CORRECTIVE <br /> ACTION INDICATED BY METHOD <br /> *V SAMPLE RESULT IS >4X SPIKED CONCENTRATION, THEREFORE SPIKE IS NOT DETECTABLE <br /> *Y RESULT NOT ATTAINABLE DUE TO SAMPLE MATRIX INTERFERENCE <br /> ,A RESULTS OUT OF LIMITS DUE TO SAMPLE NON-HOMOGENEITY <br /> @C VARIABLE A�ESSAGE <br /> @D RESULT COULD NOT BE CONFIRMED DUE TO MATRIX INTERFERENCE ON THE <br /> CONFIRMATION COLUMN <br /> @E RESULT MAY BE FALSELY ELEVATED DUE TO SAMPLE MATRIX INTERFERENCE <br /> @F RESULT OUTSIDE OF CONTRACT SPECIFIED QUALITY CONTROL LIMITS <br /> G RESULT OUTSIDE OF CONTRACT SPECIFIED ADVISORY LIMITS <br /> @DETECTION LIMIT ELEVATED DUE TO MATRIX INTERFERENCE <br /> @N <br /> @ RESULT NOT CONFIRMED BY U.V. DUE TO SAMPLE MATRIX INTERFERENCE <br /> RESULT NOT CONFIRMED BY FLUORESCENCE DUE TO SAMPLE MATRIX INTERFERENCE <br /> @P RESULT QUANTITATED USING FLUORESCENCE ONLY DUE TO THE LOW CONCENTRATION <br /> @Q DETECTION LIMIT ELEVATED DUE TO LIMITED SAMPLE FOR ANALYSIS <br /> @T RESULT DUE TO TCLP EXTRACTION MATRIX INTERFERENCE.NO QC LIMITS <br /> HAVE BEEN ESTABLISHED <br /> @U SAMPLE CHROMATOGRAM DOES NOT RESEMBLE COMMON FUEL HYDROCARBON <br /> FINGERPRINTS <br /> @Z SAMPLE CHROMATOGRAM DOES NOT RESEMBLE A FUEL HYDROCARBON <br /> g:\group sldatamgmtlmgmtlflags.do c081 10/94 <br /> I <br />