. Groundwater Monitonng Well,CPT,and Ozone Microsparge System Installation Report <br /> Tosco(76) Service Station No 11192,Stockton,California <br /> May 9 2003 <br /> Groundwater samples collected from CPT-3, the deep downgradient boring, reveal that the two <br /> groundwater zones sampled at 74 and 100 feet bgs were free of hydrocarbon impact, except for a <br /> detection of 6 8 ppb of MtBE at 100 feet bgs Again, this detection is below the established MCL <br /> for MtBE The deepest sample from CPT-3, collected at 125 feet bgs, reportedly contained <br /> concentrations of MtBE at 290 ppb and TBA at 88 ppb This deeper zone is impacted with <br /> petroleum hydrocarbons, and requires lateral definition <br /> In GR's Updated Corrective Action Plan, dated June 26, 2002, four deep groundwater monitoring <br /> wells were proposed to be installed at the site, to a depth of 80 feet bgs The results of the recent <br /> CPT investigation show that groundwater in the 75 to 80 foot bgs range does not contain MtBE at <br /> concentrations above the established MCL Although the current onsite deep well MW-11 has <br /> been reported to contain elevated concentrations of MtBE, MtBE was not detect in CPT-3 at 74 feet <br /> bgs <br /> GR recommends that three of the previously proposed onsite deep monitoring wells be installed <br /> one onsite and two off-site (Figure 6) The one onsite deep monitoring well will be constructed <br /> with a conductor casing set to approximately 110 feet bgs, with screened intervals extending from <br /> 120-130 feet bgs, depending on actual field conditions encountered during drilling (Figure 7) The <br /> two off-site deep wells will be constructed similarly to the proposed onsite deep well except there <br /> will be no conductor casing used The actual depth of the proposed screen interval will be <br /> dependent on the encountered hthology in the field Groundwater monitoring of the three proposed <br /> deep wells will allow GR to determine the flow direction of the deeper aquifer, in order to <br /> determine if the previously proposed offsite deep monitoring wells are correctly positioned in the <br /> downgradient direction Groundwater samples collected from the proposed deep wells will assist <br /> with lateral delineation of the deep dissolved hydrocarbon plume <br /> GR also recommends that a hydropunch groundwater sample be collected at a depth of <br /> approximately 75 feet bgs from the proposed deep well boring in the vicinity of MW-1 and the <br /> proposed deep well boring in the vicinity of MW-8 The result of the hydropunch samples analysis <br /> will be used to verify the presence or absence of dissolved methanol in the groundwater <br /> 7.0 REFFRENCES <br /> Gettler-Ryan Inc, 2003, Groundwater Monitoring and Sampling Report, First Quarter - Event of <br /> January 3, 2003, Tosco (76) Service Station #11192, 1403 Country Club Boulevard, Stockton, <br /> California, dated February 6, 2003 <br /> 2002, Corrective Action Plan Report, Tosco (76) Service Station No 11192, 1403 Country Club <br /> Boulevard, Stockton, California, dated March 13, 2002 <br /> 140245 8 11 <br />