Laserfiche WebLink
DEL-TECH Geotechnical Support Services <br /> MONITORING WELL FIELD LOG <br /> PROJECT NAME:Wallis Refrigeration AMPLE ANALYSIS PERFORMED TPH-GASIB T X E <br /> 1876 Country Club SAMPLE TIME- 12 32 <br /> Stockton, CA SAMPLE CONTAINER(S) 4 V O A'S <br /> ANALYSIS PERFORMED BY FGL LABS <br /> CLIENT- MANUEL SANCHEZ DATE 12/08/95 <br /> PROJECT MANAGER: BILL HUNTER SAMPLE LOCATION W-3 <br /> AMPLER DON LIGHT START TIM E• <br /> GROUNDWATER- XXX ADOSE OTHER. P I D WELL HEAD READING 327 PPM <br /> CASING ELEVATION FEET MSLCASING DIAMETER 2 INCH <br /> DEPTH TO WATER: 19 36 FEET J CALCULATED CASING VOLUME 2 20 GAL <br /> DEPTH OF WELL: 32 90 FEET OTAL VOLUME PURGED 10 0 GAL <br /> TIME VOLUME I pH E.C. TEMP COLOR OTHER <br /> gallons units Umhosicm Degrees C Visual <br /> 0 68 1849 221 CLEAR GAS ODOR <br /> 25 68 1947 229 " <br /> 50 68 1967 225 " <br /> 75 68 199 MS 225 " <br /> 100 69 200 MS 224 <br /> PURGE METHOD : CENTRIFUGAL PUMP <br /> SAMPLE METHOD. 1 FOOT STAINLESS STEEL BAILER <br /> DEPTH TO WATER AFTER PURGE: DEPTH TO WATER AT SAMPLE TIME 20 44' <br /> WELL INTEGRITY CAP AND SEAL ARE SECURE LOCK IS INSTALLED <br /> REMARKS GOOD RECHARGE <br /> WEATHER OVERCAST SKIES <br /> QUALITY CONTROL: ALL PURGING EQUIPMENT AND SAMPLING EQUIPMENT WAS CLEANED <br /> IN THE FIELD WITH ALCONOX <br /> NEW NITRILE GLOVES WERE WORN AT ALL TIMES <br /> WELL LOCATION, WELL IS LOCATED AT THE SOUTHNIlEST CORNER OF FRONT LOT <br /> CONTAINMENT: D O T 17 STEEL DRUM <br /> INSTRUMENTATION: ORION pH/TEMPERATURE METER 2 POINT pH CALIBRATION (4 0 & 7 0) <br /> ORION CONDUCTIVITY METER <br /> ENVIRONMENTAL INSTRUMENTS SLOPE METER <br /> KECK PRODUCT INTERFACE METER <br /> THERMODYNE 5808 PHOTO IONIZATION DETECTOR <br />