DEL-TECH Geotechnical Support Services <br /> MONITORING WELL FIELD LOG <br /> PROJECT NAME-Waits Refrigeration SAMPLE ANALYSIS PERFORMED TPH-GAS/B T X E <br /> 1876 Country Club SAMPLE TIME: 12 22 <br /> Stockton,CA SAMPLE CONTAINER(S) 4 V O A'S <br /> ANALYSIS PERFORMED BY- FGL LABS <br /> CLIENT* MANUEL SANCHEZ DATE: 12/08/95 <br /> PROJECT MANAGER: BILL HUNTER SAMPLE LOCATION MW-5 <br /> AMPLER: DON LIGHT START TIME: <br /> GROUNDWATER: XXX ADOSE OTHER. P I D WELL HEAD READING 0 0 PPM <br /> CASING ELEVATION FEET MSL CASING DIAMETER 2 INCH <br /> DEPTH TO WATER- 20 19 FEET CALCULATED CASING VOLUME 1 86 GAL <br /> DEPTH OF WELL: 3160 FEET TOTAL VOLUME PURGED: 8 0 GAL <br /> TIME VOLUME pH E.C. TEMP. COLOR OTHER <br /> gallons units Umbos/cm Degrees C (Visual) <br /> 0 72 1985 214 CLEAR NO ODOR <br /> 2 72 201 MS 219 " <br /> 4 72 201 MS 215 " <br /> 6 72 202 MS 206 " <br /> 8 72 201 MS 205 " <br /> PURGE METHOD : CENTRIFUGAL PUMP <br /> SAMPLE METHOD. 1 FOOT STAINLESS STEEL BAILER <br /> DEPTH TO WATER AFTER PURGE: DEPTH TO WATER AT SAMPLE TIME 20 62' <br /> WELL INTEGRITY: CAP AND SEAL ARE SECURE LOCK IS INSTALLED <br /> REMARKS* GOOD RECHARGE <br /> WEATHER- OVERCAST SKIES <br /> QUALITY CONTROL: ALL PURGING EQUIPMENT AND SAMPLING EQUIPMENT WAS CLEANED <br /> IN THE FIELD WITH ALCONOX <br /> NEW NITRILE GLOVES WERE WORN AT ALL TIMES <br /> WELL LOCATION: WELL IS LOCATED AT THE SOUTHERN MOST END OF SITE <br /> CONTAINMENT, D O T 17 STEEL DRUM <br /> INSTRUMENTATION- ORION pH/TEMPERATURE METER 2 POINT pH CALIBRATION (4 0 &7 0) <br /> ORION CONDUCTIVITY METER <br /> ENVIRONMENTAL INSTRUMENTS SLOPE METER <br /> KECK PRODUCT INTERFACE METER <br /> THERMODYNE 5806 PHOTO IONIZATION DETECTOR <br />