Laserfiche WebLink
DEL-TECH Geotechnical Support Services <br /> MONITORING WELL FIELD LOG <br /> PROJECT NAME: Welts PoWngemtmn SAMPLE ANALYSIS PERFORMED TPH-GAS/s T.X E <br /> 1876 Countl+ Club AMPLE TIME: 12A2 <br /> Stocklm, CA SAMPLE CONTAINER(S). 3 V O A'S <br /> ANALYSIS PERFORMED BY. EGL LABS <br /> CLIENT MANUEL SANCHEZ DATE 03/23/95 <br /> PROJECT MANAGER BILL HUNTER SAMPLE LOCATION MW-2 <br /> AMPLER DON LIGHT START TIME <br /> GROUNDWATER XXX ADOSE OTHER PID WELL HEAD READIN 1 300 PPM <br /> CASING ELEVATION (FEET MSL) CASING DIAMETER 2 INCH <br /> DEPTH TO WATER 20 32 FEET CALCULATED PURGE VOLUME 2 24 GAL <br /> DEPTH OF WELL 34 06 FEET iACTUAL VOLUME PER PURGE 2 5 GAL <br /> TIME, VOLUMEply E'C' TEMP. COLOR OTHER <br /> gallons units MSmbosfcm Degrees C (Visual) <br /> 0 70 203 193 LT TURBID ODOR <br /> 25 70 202 196 CLEAR GAS ODOR <br /> 50 70 202 199 " <br /> 75 70 202 194 " <br /> 100 70 201 192 " <br /> PURGE METHOD SUBMERSIBLE PUMP <br /> SAMPLE METHOD 1 FOOT STAINLESS STEEL BAILER <br /> DEPTH TO WATER AFTER PURGE 20 34' DEPTH TO WATER AT SAMPLE TIME <br /> WELL INTEGRITY CAP AND SEAL ARE NOT SECURE, LOCK IS INSTALLED <br /> REMARKS GOOD RECHARGE <br /> WEATHER OVERCAST SKIES <br /> QUALITY CONTROL ALL PURGING EQUIPMENT AND SAMPLING EQUIPMENT WAS CLEANED <br /> IN THE FIELD WITH ALCONOX <br /> NEW NITRILE GLOVES WERE WORN AT ALL TIMES <br /> WELL LOCATION WELL 1S LOCATED ON THE SOUTH/EAST CORNER OF FRONT LOT <br /> CONTAINMENT D O T 17 STEEL DRUM <br /> INSTRUMENTATION ORION pH/TEMPERATURE METER 2 POINT pH CALIBRATION (4 0 8 7 0) <br /> ORION CONDUCTIVITY METER <br /> . ENVIRONMENTAL INSTRUMENTS SLOPE METER <br /> KECK PRODUCT INTERFACE METER <br /> THERMODYNE 5806 PHOTO IONIZATION DETECTOR <br />