Laserfiche WebLink
DEL-TECH Geotechnical Support Services <br /> i <br /> MONITORING WELL FIELD LOG <br /> PROJECT NAME: Walts Refrigeration $AMPLE ANALYSIS PERFORMED TPH-GAS/B T X E <br /> 1175 Counity Club SAMPLE TIME. 7235 <br /> Stockton, Obi SAMPLE CONTAINE,R($) 3 V o A S <br /> ANALYSIS PERFORMED BY FGL LABS <br /> CLIENT MANUEL SANCHEZ ATE 03/23/95 <br /> PROJECT MANAGER BILL HUNTER AMPLE LOCATION MW-5 <br /> AMPLER DON LIGHT TART TIME <br /> GROUNDWATER XXX 11VADOSE OTHER P I D WELL HEAD READING 0 0 PPM <br /> CASING ELEVATION (FEET MSL) CASING DIAMETER 2 INCH <br /> DEPTH TO WATER 20 65 FEET CALCULATED PURGE VOLUME 1 .79 GAL <br /> DEPTH OF WELL 31 62 FEET ACTUAL VOLUME PER PURGE 2 0 GAL <br /> TIME VOLUME pH fr,C- TEMP. COLOR OTHER <br /> gallons units Msmhosfam Degrees C (Visual) <br /> 0 73 204 180 LT TURBID NO ODOR <br /> 20 74 203 188 <br /> 40 74 202 192 CLEAR <br /> 60 74 203 196 <br /> 80 74 202 195 <br /> PURGE METHOD SUBMERSIBLE PUMP <br /> SAMPLE METHOD 1 FOOT STAINLESS STEEL BAILER <br /> DEPTH TO WATER AFTER PURGE 20 70' DEPTH TO WATER AT SAMPLE TIME <br /> WELL INTEGRITY CAP AND SEAL ARE SECURE LOCK IS INSTALLED <br /> REMARKS GOOD RECHARGE <br /> WEATHER OVERCAST SKIES <br /> QUALITY CONTROL. ALL PURGING EQUIPMENT AND SAMPLING EQUIPMENT WAS CLEANED <br /> IN THE FIELD WITH ALCONOX <br /> NEW NITRILE GLOVES WERE WORN AT ALL TIMES <br /> WELL LOCATION WELL IS LOCATED AT THE SOUTHERN MOST END OF SITE <br /> CONTAINMENT D O T 17 STEEL DRUM <br /> INSTRUMENTATION ORION pH/TEMPERATURE METER 2 POINT pH CALIBRATION (4 0 & 7 0) <br /> ORION CONDUCTIVITY METER <br /> ENVIRONMENTAL INSTRUMENTS SLOPE METER <br /> KECK PRODUCT INTERFACE METER <br /> THERMODYNE 580E PHOTO IONIZATION DETECTOR <br />