Laserfiche WebLink
DEL-TECH Geotechnical Support Services <br /> • MONITORING WELL FIELD LOG <br /> PROJECT NAME:Wars Refngeraftn SAMPLE ANALYSIS PERFORMED -TPH-GASIB T.X�E <br /> 157-6 Country Club AMPLE TIME: 14,44 <br /> Stacldom OA SAMPLE Ot31+1UINER(S}: 3 V O.A'S <br /> NALYSI[S 1 SRFOAM90 SY: F'GL LABS <br /> CLIENT MANUEL SANCHEZ ATE 04/29/94 <br /> PROJECT MANAGER BILL HUNTER AMPLE LOCATION MW-3 <br /> AMPLER DON LIGHT TART TIME <br /> GROUNDWATER XXX 11VADOSE THER Well Head PID reading 456 ppm <br /> CASING ELEVATION (FEET MSL) CASING DIAMETER 2 INCH <br /> DEPTH TO WATER 20 86 FEET CALCULATED PURGE VOLUME 1 96 GAL <br /> DEPTH OF WELL 32 90 FEET 1ACTUAL VOLUME PER PURGE 2 0 GAL <br /> TIME VOLUME pal Temp- <br /> CIO. COLOR OTHER <br /> gallons -units umhostem Degrees C (Visual) <br /> 0 68 1797 21 0 LT TURBID GAS ODOR <br /> 20 69 1800 21 2 " " <br /> 40 69 1791 21 2 CLEAR " <br /> 60 70 1773 215 " <br /> PURGE METHOD ISCO PERISTALTIC PUMP <br /> SAMPLE METHOD 1 FOOT STAINLESS STEEL BAILER <br /> DEPTH TO WATER AFTER PURGE DEPTH TO WATER AT SAMPLE TIME <br /> WELL INTEGRITY CAP AND SEAL ARE SECURE LOCK IS INSTALLED <br /> REMARKS GOOD RECHARGE <br /> WEATHER CLEAR SKIES <br /> DUALITY CONTROL: ALL PURGING EQUIPMENT AND SAMPLING EQUIPMENT WAS CLEANED <br /> IN THE FIELD WITH ALCONOX <br /> NEW NITRILE GLOVES WERE WORN AT ALL TIMES <br /> WELL LOCATION WELL IS LOCATED AT THE SOUTHWEST CORNER OF LOT <br /> CONTAINMENT D O T 17 STEEL DRUM <br /> INSTRUMENTATION ORION pHITEMPERATURE METER 2 POINT pH CALIBRATION (4 0 & 7 0) <br /> ORION CONDUCTIVITY METER <br /> ENVIRONMENTAL INSTRUMENTS SLOPE METER <br /> KECK PRODUCT INTERFACE METER <br /> THERMODYNE 5808 PHOTO IONIZATION DETECTOR <br /> RECEIVED 1IM I 11994 <br />