Laserfiche WebLink
! STEP-DRAWDOWN TEST RWIA. <br /> To get some idea of the practicality of de-watering the A-zone sand a step drawdown test was <br /> performed in RW 1 A The test was performed by placing a variable speed Grundfos pump in <br /> RWIA The water was pumped through carbon to the sanitary sewer under variance from the <br /> Stockton sewer district This test lasted a period of 3 43 hours or 206 minutes During the test, the <br /> pump rate was increased in steps, starting at 0 5 gallon per minute As the drawdown in the well <br /> reaches equilibrium, the pump rate was increased in 0 5 gallon per minute increments At 1 4 <br /> gallons per minute the pump rate exceeded the rate of water entry into the well and the test was <br /> discontinued <br /> Downhole pressure transducers were used to collect drawdown information from PZ 1 A, PZ 1 B, <br /> MA, PZ2B MW 1, RW I A, and RW 1 B <br /> STEP DRAWDOWN TEST RWIB <br /> To determine the practicality of de-watering the B-Zone a Step Drawdown test was performed in <br /> RWIB The test was performed by placing a variable speed Grundfos pump in RWIB The water <br /> was pumped through carbon to the sanitary sewer under variance from the Stockton sewer district <br /> This test lasted eight hours During the test, the pump rate was increased in steps, starting at 0 8 <br /> gallons per minute As the drawdown in the well reached equilibrium, the pump rate was increased <br /> in approximately 0 5 gpm increments <br /> Downhole pressure transducers were used to collect drawdown information from PZ 1 A, PZ 1 B, <br /> MA, PZ2B MWI, RWIA, and RWIB Depth to water in the other surrounding wells were <br /> measured periodically with the depth to water meter and recorded <br /> 24 HOUR CONSTANT RATE PUMP TEST RW1A <br /> To determine the aquifer properties of the upper sand (A Zone) a constant rate pump test was <br /> performed from RW 1 A The pump was placed inRW I A and water was pumped at and average of <br /> 0 725 gpm for 24 hours The 0 725 gpm pump rate was determined by the step down test on <br /> RWIA <br /> Downhole pressure transducers were used to collect drawdown information from PZ 1 A, PZ 1 B, <br /> MA, PZ2B, MW I, RW 1 A, and RWIB Depth to water in the other surrounding wells were <br /> measured periodically with the depth to water meter and recorded <br /> 24 HOUR CONSTANT RATE PUMP TEST RWIB <br /> In order to determine the aquifer properties of the lower sand (B Zone) a constant rate pump test <br /> was performed from RWIB The pump was placed in RWIB and water was pumped for 24 hours <br /> at 4 11 gallons per minute The 4 11 gpm pump rate was determined by the step down test on <br /> RWIB <br /> 3 <br /> Pump Test 1/20-27/03 <br />