Amer;c•aii Eiwir017177ewal Net -ork <br /> WORK ORDER: 9803238 QUALITY CONTROL RE NOT PAGE QR-2 <br /> ANALYSIS: Gasoline Oxygenates <br /> MATRIX: Water <br /> METHOD BLANK SAMPLES <br /> .............................................................................................•................................ <br /> SAMPLE TYPE: B1ank•Nethod/Media blank LAB ID: BLNK_0403 INSTR RUN: GCMSIZ\980403000000/12/ <br /> INSTRUMENT: HP mass spec for Volatiles PREPARED: BATCH ID: MS12WD40398 <br /> UNITS: ug/L ANALYZED: 04/03/98 DILUTION: 1.00 <br /> METHOD: <br /> REF REPORTING SPIKE RECOVERY REC LIMITS (X) RPD <br /> ANALYTE RESULT RESULT LIMIT VALUE (X) LOW HIGH RPD (X) LIMIT (X) <br /> 1.2-DCE-d4 (surr) 90.1 100 100 90.1 70 135 <br /> Toluene-d8 (surr) 102 100 100 102 70 130 <br /> Bromofluorobenzene (surr) 90.6 100 100 90.6 70 130 <br /> Methy-t-butyl ether (MTBE) ND 5 <br /> Ethyl-t-butyl ether (ETRE) ND 5 <br /> t-Amylmethyl ether (TAME) ND 5 <br /> t-Butanol (TBA) ND 100 <br /> Di-isopropyl ether (DIPE) ND 5 <br /> SAMPLE SURROGATES .......... ..... <br /> ....................... ................ . ........................................ <br /> ............................................................................................................................. <br /> SAMPLE TYPE: Sample-Client LAB ID: 9803238.028 INSTR RUN: GCMS12\980403000000/7/ <br /> INSTRUMENT: HP mass spec for Volatiles PREPARED: BATCH ID: MS12WO40398 <br /> UNITS: ug/L ANALYZED: 04/03/98 DILUTION: 1.00 <br /> METHOD: <br /> REF REPORTING SPIKE RECOVERY REC LIMITS (X) RPD <br /> ANALYTE RESULT RESULT LIMIT VALUE (z) LOW HIGH RPD (X) LIMIT (X) <br /> 1.2•DCE•d4 (surr) 97.3 100 100 97.3 70 135 <br /> Toluene-dB (surr) 106 100 IOD 106 70 130 <br /> Bromof......luorobenzene...... (sur.) 87.9 ............... ........ 100.....__ ... .......70 130._._.._................_._ <br /> MATRIX: Soil/Bulk <br /> METHOD BLANK SAMPLES <br /> SAMPLE TYPE: Blank-Method/Media blank LAB ID: BLNK 0403 INSTR RUN: GCMS12\980403180000/1/ <br /> INSTRUMENT: HP mass spec for Volatiles PREPARED: BATCH ID: MS12SO40398 <br /> UNITS: ug/kg ANALYZED: 04/03/98 DILUTION: 1.00 <br /> METHOD: <br /> REF REPORTING SPIKE RECOVERY REC LIMITS (X) RPD <br /> L ANALYTE RESULT RESULT LIMIT VALUE (X) LOW HIGH RPD (X) LIMIT (X) <br /> 1.2-DCE•d4 (surr) 113 100 100 70 145 <br /> Toluene-d8 (surr) 103 100 100 70 145 <br /> Bromofluorobenzene (surr) 100 100 100 70 145 <br /> Methyy•t•butyl ether (MTBE) ND 5 <br /> Ethyl•t-butyl ether (ETBE) ND 5 <br /> t•Amylmethyl ether (TAME) NO 5 <br /> t•Butanol (TBA) ND 100 <br /> LD......ropyl...... (DIPE).......... ....................NO 5.... ............................................................... <br /> SAMPLE SURROGATES <br /> SAMPLE TYPE: Sample•Client LAB ID: 9803238.01A INSTR RUN: GCMS12\980403180000/3/ <br /> INSTRUMENT: HP mass spec for Volatiles PREPARED: BATCH ID: MS12SO40398 <br /> UNITS: ug/kg ANALYZED: 04/03/98 DILUTION: 1.00 <br /> METHOD: <br /> REF REPORTING SPIKE RECOVERY REC LIMITS (1) RPD <br /> ANALYTE RESULT RESULT LIMIT VALUE (X) LOW HIGH RPD (X) LIMIT (X) <br /> 1.2•DCE-d4 (surr) ' 91.0 100 100 91.0 70 145 <br /> L4 Toluene-d3 (surr) 112 - 1D0- •• 100_• _ 112 70••' 145 ...................... <br /> Bromofluorobenzene (surr). ..._89.4 100 100 89.4 70 145 <br />