Laserfiche WebLink
r � <br /> CAM B R [ A <br /> IPA 150 1, and for total pctrolcum hydrocarbons by I-PA 1664 GWE system effluent analyt]cal <br /> data are summarized in Table I <br /> Analytical Resulh Lahoratory analytic it results indicate that samples taken from our final discharge <br /> point were below the permit-specified discharge limits for all analyzed con,tttuc.nts Appendix A <br /> presents the certified laboratory report for the rcquned monthly samples collected on <br /> November 14, 2005 <br /> Monthly Flow Data Between October 24 and November 28,2005,the total discharge to the sanitary <br /> sewer was 6,156 gallon-, which corresponds to an average flow rate of 0 12 gallons per minute <br /> Discussion Most of the GWE system equipment,excluding the carbon treatment vessels was Stolen <br /> from the site between November 21 and NoN ember 28 2005,rendering the system inoperable Since <br /> GWE system redesign plans are already underway, no discharge will take place until the new GWE <br /> system is installed The new system will be built to comply with the revised permit requirement for <br /> hard piping except for the connections between carbon treatment vessels <br /> • <br /> • <br />