Laserfiche WebLink
1 <br />' 1 INTRODUCTION <br />' Former Exxon Retail Site {RS) 7-3708 is an active U S A Petroleum station located at 2705 Country <br /> Cluh Boulevard in Stockton, Cahfomia, at the northwest comer of the intersection of Ryde Avenue <br />' and Country Club Boulevard Elevation of the ground surface at the site is approximately 1 to 2 feet <br /> above mean sea level The site slopes down toward the northeast and southwest corners from a <br /> slight topographic high across the center <br />' There are two underground storage tanks at the site containing diesel fuel and unleaded gasoline <br /> Groundwater monitoring has been conducted at the site since 1991 <br />' 2 GROUNDWATER MONITORING <br />' On 6 November 2000, wells MW 1 and MW4-MW 10 were gauged for depth to water and for liquid- <br /> phase hydrocarbons (LPH) with an optical interface probe Groundwater samples were collected <br /> from these wells and the samples were analyzed for Total Petroleum Hydrocarbons as gasoline <br />' (TPH-g), for benzene, toluene, ethylbenzene, and total xylenes (BTEX), and for methyl t-butyl ether <br /> (MTBE) <br />' The current depth-to-water measurements and calculated groundwater elevations are presented in <br /> boldface type in Table 1, along with previous data Current groundwater elevations are also shown <br /> in Figure 1 The groundwater flow direction on 6 November was to the northeast, with a gradient <br />' of approximately 0 0005 LPH was not observed in any of the wells <br /> ,kfter the depths to water were measured the wells were purged Field parameters of pH, <br />' temperature, and electrical conductance of the purged water were measured for approximately every <br /> well casing volume during purging Field documents are included in Appendix A When the field <br /> parameters were stable (less than a 10 percent change from the previous reading for temperature and <br />' electrical conductance and not more than 0 1 pH units) and approximately 3 casing volumes were <br /> removed from each well, purging was stopped and samples were collected, using factory-cleaned <br /> disposable bailers The samples were poured into 40-m1 glass VOA vials and stored in an ice-filled <br />' cooler Ail samples were handled and transported under chain of custody <br /> The samples were submitted to SPL, Inc in Houston, Texas, and were analyzed for TPH-g by Cal <br />' EPA-modified EPA Method 8015 and for BTEX and MTBE by EPA Method 8021B The samples <br /> were also analyzed for MTBE by EPA Method 8260B The results are presented in boldface type, <br /> along with previous analytical data, in Table 1, and are shown in Figure 1 The laboratory analytical <br />' report and chain-of-custody documentation are included in Appendix B <br />' 3 WORK PROPOSED FOR NEXT QUARTER <br /> Groundwater will be gauged and sampled in February 2001 Groundwater samples will be analyzed <br />' for TPH-g, BTEX, and MTBE <br /> 1 <br /> h Itt,«6 -[ti Mnu lLF UlioI .1 1 <br />