Laserfiche WebLink
' HOUSTON LABORATORY <br /> 8880 INTERCHANGE DRIVE <br /> HOUSTON TEXAS 77054 <br /> ® <br /> (713)660-0901 <br /> Quality Control Report <br /> EXXON Company U S A <br /> 000517-J2 <br /> Lalysis Purgeable Aromatics WorkOrder 00050536 <br /> Method SW8021 B Lab Batch ID R14357 <br /> Matrix Spike MS /Matrix Spike Duplicate MSD <br /> Sample Spiked 00050536-01 <br />' RunlD H?_R_000519A 286108 Units uglL <br /> Analysis Date 05119/2000 15 53 Analyst DL <br /> Analyte Sample MS MS Result IMS% MSD MSD Result MSD% RPD RPD , Low High <br /> Result Spike Recovery I Spike I Recovery Limit Limit Limit <br /> Added j Addedi <br /> oluene ND 20 18, 92 2 20I 19, 93 T 1 48! 20' 38 1591 <br /> p-Xylene ND 40 36I 898 40i, 36 90 0{0 192' 17 53 144 <br /> io-, <br /> Xylene NDI 20I 18I 90 8 20 18 91 0,0 154 18 53 143 <br /> ylenes Total ND 60 5411 900 G0 54 900 0 18 53 144 <br /> 1 <br /> 1 <br /> alifiers NDIU-Not Detected at the Reporting Limit *-Recovery Outside Advisable QC Limits <br /> B-Analyte detected in the associated Method Blank D-Recovery Unreportable due to Dilution <br /> J-Estimated value between MDL and PQL MI -Matrix Interference <br /> 00050535!'age 12 <br /> 611100 8 51 17 AP <br />