Laserfiche WebLink
Lisa Medina [EH] <br /> From: Lisa Medina [EH] <br /> Sent: Wednesday,June 05, 2013 4:04 PM <br /> To: 'Magee,Amanda' <br /> Cc: Lichtenberger, Deborah; Manning, Danielle;Tanner,Jennifer; Nuel Henderson [EH]; <br /> Adrienne Ellsaesser [EH] <br /> Subject: RE:7-11#14117, 2725 Country Club Boulevard, Stockton, well destruction <br /> Hello Amanda, <br /> The EHD has reviewed and evaluated analytical data and well construction of MW-2 in order to address your request <br /> for variance from SJC Well Standards. Upon further review, it has been determined that a variance cannot be granted <br /> due to the following: <br /> 1) Review of the boring log and well construction table shows that MW-2 is screened from 5 to 25 feet,which <br /> includes most of the conductor casing; <br /> 2) Soil encountered during advancementof the well boring was impacted by hydrocarbon contaminants; <br /> 3) The well is not screened in native soil (only) as previously thought and soil is impacted; <br /> 4) MW-2 is to be destroyed through the conductor casing.by removal of the well contents and not by pressure <br /> grouting as previously discussed. <br /> If you should have any questions please do not hesitate to call.Regards. <br /> Lisa Medina, Senior REHS <br /> San Joaquin County Environmental Health Department <br /> 1868 East Hazelton Avenue <br /> Stockton,CA 95205 <br /> (209)468-3455 <br /> Imedina(@sicehd.com <br /> °4C_ > <br /> "SIC Environmental Health Department strives to provide service excellence to our customers, constituents and <br /> stakeholders"LM <br /> 1 <br /> y� <br />