Laserfiche WebLink
• Commercd Electric <br /> S mith® <br /> Water Heaters <br /> DURA-POWERTM <br /> Designed for use as a recovery heater having its own storage tank.Available in <br /> upright standard models(DEN)and lowboy models(DEL). <br /> GLASSLINED TANK SIMPLIFIED CIRCUITRY, COLOR <br /> • Thirteen sizes;6 thru 119 gallon CODED FOR EASE OF SERVICE -•- <br /> capacity.Tank interior iscoatedwith ANODE ROD FOR MAXIMUM 7r�smlt^ <br /> glass specially designed by A.O.Smith CORROSION PROTECTION <br /> for water heater use. <br /> CABINET HAS BONDERIZED <br /> ELEMENTS UNDERCOAT WITH BAKED <br /> • Zinc plated copper sheaths for longer ENAMEL FINISH <br /> life.Medium watt density means lower TOP INLET AND OUTLET OPENINGS <br /> surface temperature to minimize scale <br /> build-up and more surface to heat DRAIN VALVE <br /> water.Element sizes from 1.5 to 6 KW (EXCLUDES DEL 6-20) <br /> Maximum input 12 KW(see chart). UL APPROVED FIELD CONVERSION <br /> STANDARD VOLTAGES PROGRAM <br /> • 120,277 single phase and 208,240 COMPLIANCE ' <br /> and 480V unbalanced three-phasemama <br /> • Meets the standby loss Requirements <br /> delta;easily converted to single-phase at of the U.S.Department of Energy and <br /> terminal block(except 208V with 6000 <br /> current edition of ASHRAE/IESNA 90.1. <br /> watt elements).Single element heaters, <br /> single-phase only. LIMITED WARRANTY OUTLINE <br /> TERMINAL BLOCK If the tank should leak any time during -- <br /> • Fthe first three years,under the terms of <br /> Factory-installed.Just bring these vice <br /> to heater and connect to block.Terminal the warranty,A. Smith will furnish a <br /> block not supplied on 120V&277 volt replacement heater;installation,labor, <br /> models.(No junction box on DEL6-20) OUTLIhandeNE <br /> ing and local delivery extra.THIS <br /> OUTLINE IS NOT A WARRANTY.For <br /> CONTROLS complete information consult the written <br /> • Temperature control(adjustable warranty or A.O.Smith Water Products <br /> through arange of 110°to 170°F on Company. cas, <br /> single element and 120°to 181°F on <br /> dual element)and manual reset high <br /> temperature cutoff per element(dual <br /> element models).Factory-wired for non- <br /> simultaneous operation;easily converted <br /> to simultaneous element operation(three <br /> phase models only). <br /> CSA CERTIFIED AND ASME RATED <br /> T&P RELIEF VALVE <br /> ©August 2015 A.0.Smith Corporation.All rights reserved. Page 1 of 4 <br /> www.hotwatercom 1810-527-1953 Toll-Free USA IA.0.Smith Corporation 1500 Tennessee Waltz Parkway I Ashland City,TN 37015 AOSCE15400 <br />