Laserfiche WebLink
Table B-Historical Diesel Thickness Measurements and Product Recovery Data <br /> (6/18/99 through 11/9/05) <br /> Date n Recovery Depth to Depth to Diesel Cumulative Operations and Maintenance Notes <br /> Well Floating Groundwater Thickness Diesel <br /> Diesel Removed <br /> (gallons) <br /> RW-2 12.93 12.95 0.02 19.70 <br /> Product recovery barrel measurement indicated approximately 46.25 gallons of product; <br /> system sensor stopped pumping due to tank full status.Full tank removed and replaced <br /> with an empty recovery barrel;skimmer pump set to continuous mode.Full product <br /> barrel set next to diesel AST basin.Absorbent socks in RW-2 and RW-3 strained;a <br /> negligible amount of product recovered. Skimmer pump in RW-4 removed <br /> 3/17/03 RW-3 12.76 13.32 0.56 2.30 approximately 0.5 gallons of product.Skimmer puup removed from RW-4 and installed <br /> in RW-3.Cycle remained on continuous mode until no additional product was removed; <br /> cycle then set on(3)5-minute cycles/day.Absorbent socks placed in RW-2 and RW-4. <br /> Approximately 1.0 gallon ofproduct was measured in the new recovery barrel.Half inch <br /> metal bars and orange safety tape was placed around the skimmer pump for added <br /> visibility. <br /> .RW-4 12.62 12.63 - 0.01 40.45 <br /> RW-2 12.93 12.98 0.05 19.70 <br /> .. Skimmer pump installed in RW-3 was inspected and the N2 tank exchanged.The system <br /> regulator was not functioning and required repair.Cycle set on(1)5-minute cycle/day. <br /> The recovery sock from RW-4 was strained and replaced,and free product from the well <br /> 4/2/03 RW-3 12.97 13.17 0.20 2.30 was bailed; approximately 2 gallons was added to the product recovery barrel. <br /> Insufficient product available in RW-2 for bailing to be effective.The recovery sock in <br /> RW-2 was strained and replaced;a negligible amount of product was recovered.Post <br /> bailing measurement of the product recovery barrel indicated approximately 3 gallons of <br /> product. _ - <br /> RW-4 11.91 15.24 3.33 42.45 <br /> RW-2 13.06 13.12 0.06 19.70 <br /> The skimmer pump regulator and battery were not operational.The line pressure was <br /> functional;however,the tank pressure was not.Absorbent socks in RW-2 and RW-4 <br /> 4/13/03 RW-3 13.19 13.39 0.30 2.80 strained;a negligible amount of product recovered.Skimmer pump removed from RW- <br /> 3 and installed in RW-4. Recovery socks were reinserted in RW-2 and RW-3. <br /> Approximately 3.5 gallons in product recovery barrel. <br /> RW-4 12.02 15.58 3.56 42.45 <br /> RW-2 13.06 13.14 0.08 19.70 <br /> Skimmer pump removed from RW-4 and inspected.Skimmer pump was reinstalled in <br /> RW-4 and the pump cycle set at(6)5-minute cycles/day.The N2 tank supply tank and <br /> 4/25/03 RW-3 13.02 13.51 0.49 2.80 battery were replaced and a new regulator was purchased and installed.The pump cycle <br /> was reset at(3)3-minute cycles per day.Absorbent socks in RW-2 and RW-3 strained <br /> and replaced;a negligible amount of product recovered.Approximately 10.5 gallons in <br /> product recovery barrel. <br /> RW-4 12.58 13.05- 0.47. 49.45 <br /> RW-2 13.16 13.37 0.21 19.70 <br /> Initial measurement of the product recovery barrel indicated approximately 22.75 <br /> gallons of diesel product Skimmer pump left in RW-4;pump cycle reset to(1)5-minute <br /> 5/22/03 RW-3 13.02 14.34 1.32 3.80 cycle/day. Absorbent socks in RW-2 and RW-3 removed and strained; a negligible <br /> amount of product recovered.Approximately 1 gallon of free product was bailed from <br /> RW-3 and added to the product recovery barrel.The absorbent socks were replaced in <br /> RW-2 and RW-3.Approximately 23.75 gallons in product recovery barrel. <br /> RW-4 12.77 12.82 0.05 61.70 <br /> Table B 111005 - Page 5 of 11 <br />