My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS XR0003317
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
D
>
DA VINCI
>
4627
>
2900 - Site Mitigation Program
>
PR0543804
>
ARCHIVED REPORTS XR0003317
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/28/2019 4:11:02 PM
Creation date
6/28/2019 2:03:15 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0003317
RECORD_ID
PR0543804
PE
2950
FACILITY_ID
FA0024907
FACILITY_NAME
7-ELEVEN STORE #20632
STREET_NUMBER
4627
STREET_NAME
DA VINCI
STREET_TYPE
DR
City
STOCKTON
Zip
95207
CURRENT_STATUS
01
SITE_LOCATION
4627 DA VINCI DR
P_LOCATION
01
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
58
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
7-Eleven Store#20632 <br /> Quarterly Groundwater Monitoring Report (3Q2003) <br /> • November 25, 2003 <br /> Page 2 <br /> Current Quarter Analytical Data (See Figure 3 and Table 1) <br /> Maximum TPHg Concentrations MW-3, 750 ug/L <br /> Maximum Benzene Concentrations MW-5, 0 52 u /L <br /> Maximum MtBE Concentrations MW-7, 47,000 ug/L <br /> Maximum TBA Concentrations MW-4R, 75,000 ug/L <br /> BACKGROUND <br /> Initial site assessment activities were executed in accordance with directives from SJCEHD <br /> requirements (Fluor Daniel GTI 1997) The assessment concluded that soil impacted with gasoline <br /> appeared restricted to a limited area surrounding the underground storage tank (UST) pit and <br /> underlying the fuel dispensers The USTs were replaced as part of 1998 upgrading requirements <br /> Concurrent with limited overexcavation, several days of high-volume dewatering occurred as part of <br /> construction activities, which also served as a short-term remediation event <br /> Additional lateral and vertical assessment of dissolved methyl-tert-butyl ether (MtBE) and <br /> hydrocarbons has been conducted There are currently seven onsite monitoring wells In April <br /> 2002, three onsite monitoring wells (MW-4R, MW-6, and MW-7), two dual-nested sparge/vent wells <br /> (SPV-1 and SPV-2) and a vertical delineation soil boring (SB-1) were installed at the site <br /> On April 22, 2002, a soil vapor extraction (SVE) test was performed at the site Vapor was extracted <br /> from MW-4R, MW-7, SPV-1, and SPV-2 Low influent vapor concentrations and poor vacuum <br /> response in observation wells were observed during the test AN air sparge test in SPV-1 increased <br /> the dissolved oxygen concentration from 0 5 to 2 4 mg/L in SPV-1 <br /> In April 2003, 7-Eleven, Inc upgraded the product lines at the site Benzene, total petroleum <br /> hydrocarbons as gasoline (TPHg), and MtBE were reported at maximum concentrations of 0 019 <br /> milligrams per kilogram (mg/kg), 4 7 mg/kg, and 0 60 mg/kg, respectively, in soil samples collected <br /> beneath the product lines and fuel dispensers <br /> MONITORING AND SAMPLING PROCEDURES <br /> The depth to water was measured in monitoring wells MW-1, MW-2, MW-3, MW-4R, MW-5, MW-6, <br /> and MW-7, from top of casing (TOC) using a water level indicator to within 0 01 feet bgs Dissolved <br /> oxygen readings were also collected from each well using a YSI Model 550A dissolved oxygen meter <br /> equipped with a down hole sensor <br /> Well purging and sampling equipment is thoroughly cleaned prior to purging and sampling each well <br /> The sampling procedure for each well includes measuring the water level and checking for the <br /> presence of liquid-phase hydrocarbons (LPH), using either an electronic indicator and a clear <br /> Teflon® bailer or an o[l-water interface probe Wells not containing LPH are purged of approximately <br /> three casing volumes of water (or to dryness) using a submersible pump or bailer The equipment <br /> and purging methods used for the current sampling event are noted on the field data sheets included <br /> in Attachment A During purging, temperature, pH, and electrical conductivity are monitored in order <br /> to document that these parameters are stable prior to collecting samples After purging, water levels <br /> are allowed to recover to 80% of the original levels prior to collection of the water sample <br /> • Groundwater samples are collected using a disposable Teflon® bailer, placed into appropriate EPA- <br /> approved containers, labeled, logged onto chain-of-custody documents, and transported on ice to a <br /> California state-certified laboratory Copies of the field notes have been included in Attachment A <br /> 20632 03-30 Report doc SECOR International incorporated <br />
The URL can be used to link to this page
Your browser does not support the video tag.