Laserfiche WebLink
7-Eleven Store#20632 <br /> • Quarterly Groundwater Monitoring Report(2Q2003) <br /> August 27, 2003 <br /> Page 2 <br /> Current Quarter Analytical Data (See Figure 3 and Table 1) <br /> Maximum TPHg Concentrations MW-4R, 1,400 u IL <br /> Maximum Benzene Concentrations MW-4R, 52 u IL <br /> Maximum MtBE Concentrations MW-7, 54,000 u IL <br /> Maximum TBA Concentrations MW-4R, 170,000 a 1L <br /> BACKGROUND <br /> Initial site assessment activities were executed in accordance with directives from SJCEHD <br /> requirements (Fluor Daniel GTI 1997) The assessment concluded that soil impacted with gasoline <br /> appeared restricted to a limited area surrounding the underground storage tank (UST) pit and <br /> underlying the fuel dispensers The UST's were replaced as part of 1998 upgrading requirements <br /> Concurrent with limited overexcavation, several days of high-volume dewatering occurred as part of <br /> construction activities, which also served as a short-term remediation event <br /> Additional lateral and vertical assessment of dissolved methyl-tert-butyl ether (MtBE) and <br /> hydrocarbons has been conducted There are currently seven site-related monitoring wells In April <br /> 2002, three onsite monitoring wells (MW-4R, MW-6, and MW-7), two dual-nested sparge/vent wells <br /> • (SPV-1 and SPV-2) and a vertical delineation soil boring (SBA) were installed at the site <br /> In April 2003, 7-Eleven, Inc upgraded the product lines at the site Benzene, total petroleum <br /> hydrocarbons as gasoline (TPHg), and MtBE were reported at maximum concentrations of 0 019 <br /> mglkg, 4 7 mg/kg, and 0 60 mg/kg, respectively, in soil samples collected beneath the product lines <br /> and fuel dispensers <br /> MONITORING AND SAMPLING PROCEDURES <br /> The depth to water was measured in monitoring wells MW-1, MW-2, MW-3, MW-4R, MW-5, MW-6, <br /> and MW-7, from top of casing (TOC) using a water level indicator to within 0 01 feet bgs Dissolved <br /> oxygen readings were also collected from each well using a YSI Model 550A dissolved oxygen meter <br /> equipped with a down hole sensor <br /> Well purging and sampling equipment is thoroughly cleaned prior to purging and sampling each well <br /> The sampling procedure for each well includes measuring the water level and checking for the <br /> presence of liquid-phase hydrocarbons (LPH), using either an electronic indicator and a clear <br /> Teflon® bailer or an oil-water interface probe Wells not containing LPH are purged of approximately <br /> three casing volumes of water (or to dryness) using a submersible pump or bailer The equipment <br /> and purging methods used for the current sampling event are noted on the field data sheets included <br /> in Attachment A During purging, temperature, pH, and electrical conductivity are monitored in order <br /> to document that these parameters are stable prior to collecting samples After purging, water levels <br /> are allowed to recover to 80% of the original levels prior to collection of the water sample <br /> Groundwater samples are collected using a disposable Teflon® bailer, placed into appropriate EPA- <br /> approved containers, labeled, logged onto chain-of-custody documents, and transported on ice to a <br /> California state-certified laboratory Copies of the field notes have been included in Attachment A <br /> GROUNDWATER SAMPLE ANALYSES AND RESULTS <br /> The groundwater samples collected from MW-1, MW-2, MW-3, MW-4R, MW-5, MW-6, and MW-7 <br /> were analyzed for the presence of total petroleum hydrocarbons as gasoline (TPHg), benzene, <br /> toluene, ethylbenzene, and total xylenes (BTEX), and fuel oxygenates MtBE, tert-butyl alcohol <br /> 20632 03-20 Report doc SECOR International Incorporated <br />