My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS XR0003325
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
D
>
DA VINCI
>
4627
>
2900 - Site Mitigation Program
>
PR0543804
>
ARCHIVED REPORTS XR0003325
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/28/2019 3:28:14 PM
Creation date
6/28/2019 2:34:31 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0003325
RECORD_ID
PR0543804
PE
2950
FACILITY_ID
FA0024907
FACILITY_NAME
7-ELEVEN STORE #20632
STREET_NUMBER
4627
STREET_NAME
DA VINCI
STREET_TYPE
DR
City
STOCKTON
Zip
95207
CURRENT_STATUS
01
SITE_LOCATION
4627 DA VINCI DR
P_LOCATION
01
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
41
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
(OHI.LA.B CORE LABORATORIES <br /> Q U A L I T Y A S S U R A N C E F 0 0 T E R <br /> METHOD REFERENCES <br /> (1) EPA SV-846, Test Methods for Evaluating Solid Waste, Third Edition, September 1986, and Updates I, II, IIA, IIB, and III <br /> (2) Standard Methods for the Examination of hater and Wastewater, 18th Edition, 1992 <br /> (3) EPA 600/4-79-020, Methods of Chemical Analysis for Waters and Wastes, March 1983 <br /> (4) Federal Register, Friday, October 26, 1984 (40 CFR Part 136) <br /> (5) American Society for Testing and Materials, Volumes 5 01, 5 02, 5 03, 1992 <br /> (6) EPA 600/4-89-001, Short-term Methods for Estimating the Chronic Toxicity of Effluents and Receiving Waters to Fresh <br /> Water Organisms <br /> (7) EPA 600/4-90-027, Methods for Measuring the Acute Toxicity of Effluent and Receiving Waters to Fresh Water and Marine <br /> Organisms, Fourth Edition <br /> COMMENTS <br /> All methods of chemical analysis have a statistical uncertainty associated with the results. Unless otherwise indicated, <br /> the data in this report are within the Limits of uncertainty as specified in the referenced method Quality control <br /> acceptance criteria are based either on Limits specified in the referenced method or on actual laboratory performance <br /> The date and time of analysis indicated on the QC report may not reflect the actual time of analysis for QC samples. Data <br /> reported in the QA report may be lower than sample data due to dilution of samples into the calibration range of the analysis <br /> Sample concentrations for solid samples are calculated on an as received (wet) basis unless otherwise indicated. Unless <br /> otherwise indicated, volatiles by gas chromatography (GC) are reported from a single column Volatiles analyses by GC on low <br /> Level soils are conducted at room temperature TCLP extractions are performed at sample amounts, approved by the State of <br /> California <br /> FLAGS, FOOTNOTES, AND ABBREVIATIONS (as needed) <br /> NA = Not analyzed H I. = Not Ignitable <br /> N/A = Not applicable S I. = Sustains Ignition <br /> ug/L = Micrograms per liter I(NS) = Ignites, but does not Sustain Ignition <br /> mg/L = Milligrams per liter RPD = Relative Percent Difference <br /> NO = Not detected at a value greater than the reporting limit <br /> NC = Not catcuLable due to values Lower than the detection limit <br /> (a) = Surrogate recoveries were outside acceptable ranges due to matrix effects <br /> (b) = Surrogate recoveries were not calculated due to dilution of the sample below the detectable range for the surrogate. <br /> (c) = Matrix spike recoveries were outside acceptable ranges due to matrix effects. <br /> (d) = Relative Percent Difference (RPD) for duplicate analysis outside acceptance Limits due to actual differences in <br /> the sample matrix. <br /> (e) = The Limit Listed for flammability indicates the upper Limit for the test Samples are not tested at temperatures <br /> above 140 Fahrenheit since onty samples which wilt sustain ignition at temperatures below 140 are considered <br /> flammable. <br /> (f) = Results for this hydrocarbon range did not match a typical hydrocarbon pattern. Results were quantified using a <br /> diesel standard, however, the hydrocarbon pattern did not match a dieseL pattern. <br /> (g) = Results for this hydrocarbon range did not match a typical hydrocarbon pattern. Results were quantified using a <br /> gasoline standard, however, the hydrocarbon pattern did not match a gasoline pattern. <br /> (h) = High dilution due to matrix effects <br /> QC SAMPLE IDENTIFICATIONS SUBCONTRACTED LABORATORY LOCATIONS <br /> M8 = Method Blank S8 = Storage Blank Core Laboratories: Aurora, Colorado *AU <br /> RS = Reagent Blank MS = Matrix Spike Casper, Wyoming *CA <br /> ICS = Initial Calibration Stank MSD = Matrix Spike Duplicate Corpus Christi, Texas *CC <br /> CCB = Continuing Calibration Blank MD = Matrix Duplicate Edison, New Jersey *ED <br /> CS = Calibration Standard BS = Blank spike Houston, Texas (Env) *HE <br /> ICY = Initial Calibration SS = Surrogate Spike Houston, Texas (Pet) *HP <br /> verification LCS = Laboratory Control Indianapolis, Indiana *IM <br /> CCV = Continuing Calibration Standard Lake Charles, Louisiana *LC <br /> Verification RS = Reference Standard Long Beach, California *LS <br /> Valparaiso, Indiana *VP <br /> Bakersfield, California *BK <br /> 1250 Gene Autry Way Autry Way <br /> Anaheim, CA 92805 <br /> (714) 937-1094 /u/matt/logs n_forms/footer.form <br /> ��m�a <br /> o 1, <br />
The URL can be used to link to this page
Your browser does not support the video tag.