Laserfiche WebLink
Canonie Environmental Case Narrative <br /> Client- ENVIRONMENTAL SOLUTIONS Project # -L90076 • <br /> LP #: 9955 <br /> Inorganics Case Narrative <br /> Due to matrix interference, the reporting limits have been <br /> raised to 5 . 0 mg/Kg for selenium and 10. 4 mg/Kg for arsenic <br /> The antimony digestion spike recovery was only 22% . The <br /> post spike for antimony was within the control limits <br /> The nickel RPD was 27 . 4%, slightly higher than the 20% <br /> control limit . The analyses were completed in accordance <br /> with SW 846 protocol , <br /> Pesticides Case Narrative <br /> TEH: This narrative covers the analysis of 1 sample in ac- <br /> cordance with SW 846, 3rd. ED. The specified holding time <br /> for this analysis was met. Surrogates were not used in this <br /> analysis . Spike recoveries were within acceptable limits . <br /> The method blank did not contain any target compounds or <br /> interfering peaks at or above the reporting limits . Continu- <br /> ing calibration criteria was met for this analysis _ <br /> OCP : Calibration was verified for all samples analyzed. <br /> The method blank was free from interferences at or above the <br /> reporting limits . Two non-target peaks were detected in the <br /> blank, but they did not affect the target compounds . <br /> Interferences in sample SD-A3 (855870) exceeded the spike . <br /> concentration and required a dilution for analysis, which <br /> invalidates any recovery data- <br /> Extractions Pest . Case Narrative <br /> TEH- <br /> All samples were extracted within required holding time by <br /> method 3550 . Stockpile composite (855880) has a final <br /> volume of 10 . 0 mis due to difficulty in volume reduction- <br /> OCP-8080 <br /> All samples were extracted within required holding time by <br /> method 3540 . A THA clean-up was performed to remove sulfur <br /> compounds . Final volume was 10. 0 mis , <br /> GC/MS Case Narrative - Volatile <br /> The sample was analyzed for volatile organics in accordance <br /> with QC criteria specified in SW846 Method 8240 within the <br /> required holding time- The tuning and standard calibrations, <br /> blank, internal standard areas/retention times, surrogate <br /> and spike recoveries were within acceptable QC guidelines _ <br /> The blank and sample had methylene chloride present which <br /> was fudged a laboratory artifact and not reported. <br /> GC/MS Semivolatile Case Narrative <br /> The soil sample was analyzed for semivolatile compounds in <br /> accordance with QC criteria specified in SW846 Method 8270 . <br /> The sample was analyzed withing required holding times . The • <br /> blank was acceptable within QC criteria limits . The tuning <br /> calibration and standards calibrations all met QC criteria. <br /> The internal standard areas, retention time and surrogate l <br /> recoveries met QC criteria guidelines. :ate iii N"rohmental <br />