Laserfiche WebLink
Kennedy/Jenks Consultants <br /> Table 3: Measures for Level C Decontamination <br /> Station Description <br /> 1 Equipment Drop <br /> Deposit equipment used onsite(tools,sampling devices and containers,monitoring instruments,radios,clipboards,etc.)on plastic drop <br /> • cloths.Segregation at the drop reduces the probability of cross contamination. During hot weather operations,a cool down station may <br /> be set up within this area. <br /> 2 Outer Garment,Boots,and Gloves Wash and Rinse <br /> Scrub outer boots,outer gloves and splash suit with decon solution or detergent water. Rinse off using copious amounts of water. <br /> 3 Outer Boot and Glove Removal <br /> Remove outer boots and gloves. Deposit in container with plastic liner. <br /> 4 Canister or Mask Change <br /> If worker leaves Exclusion Zone to change canister(or mask),this is the last step in the decontamination procedure.Worker's canister is <br /> exchanged, new outer gloves and boot covers donned,joints taped,and worker returns to duty. <br /> 5 Boot,Gloves and Outer Garment Removal <br /> Boots,chemical-resistant splash suit,inner gloves removed and deposited in separate containers lined with plastic. <br /> 6 Face Piece Removal <br /> Facepiece is removed.Avoid touching face with fingers. Facepiece is deposited on plastic sheet. <br /> 7 Field Wash <br /> Hands and face are thoroughly washed. Shower as soon as possible. <br /> BNSF Mormon Yard—Soil Sampling HASP <br /> Mormon Yard, Stockton, California Page 1 of 1 <br /> Kennedy/Jenks Consultants©,March 2015 <br /> gAs upWminyW1M36.` .00_MW4pjWmFNaTWv,dm <br />