My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS XR0003281
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
D
>
DIAMOND
>
1050
>
2900 - Site Mitigation Program
>
PR0001781
>
ARCHIVED REPORTS XR0003281
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/3/2019 1:07:55 PM
Creation date
7/3/2019 10:38:09 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0003281
RECORD_ID
PR0001781
PE
2960
FACILITY_ID
FA0004090
FACILITY_NAME
DIAMOND WALNUT GROWERS INC
STREET_NUMBER
1050
STREET_NAME
DIAMOND
STREET_TYPE
ST
City
STOCKTON
Zip
95205
APN
155 320 19 5
CURRENT_STATUS
01
SITE_LOCATION
1050 DIAMOND ST
P_LOCATION
01
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
133
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
LABORATORY NARRATIVE <br /> Modified RSK 175 <br /> Prima Environmental <br /> Workorder# 0410487 <br />' Nine VOA Vial-40 nL samples were received on October 22, 2004 The laboratory performed analysts via <br /> Modified RSK 175 for Methane using GC/FID Tile method involves placing an aliquot of the sample in a <br />' headspace vial. The vial is then placed into HP7694 Headspace Autosampler equipped with oven, shaker <br /> and 1 rrL sample loop Sample is incubated and then equilibrated at 400C for 15 minutes with high agitation. <br /> Filially, a direct injection of the headspace is performed See the data sheets for the reporting limits for each <br />' compound <br /> Requirement RSK 175 AFL Modifications <br /> Sample Collection Collect sample in 60 mL Collect sample in 40 mL VOA vial <br /> cramp-top vial <br /> Headspace Generation Headspace is generated 5 0 mL of sample is displaced with 5 0 mL Nitrogen and <br /> in 60 mL sample vial by transferred to a Nitrogen purged and capped autosampler <br /> displacing volume of vial Headspace is then generated in the autosampler vial <br /> liquid with Helium The <br /> amount of liquid should <br /> be 10%of sample <br /> volume in bottle,up to <br /> 10 ml- <br /> Sample <br /> LSample Preparation Sample is shaken 5 min Prior to injection,autosampler shakes sample for 15 min <br /> to equilibrate analyte while heating to 40'C <br /> between headspace <br /> and liquid phase <br />' Headspace Injection Syringe injection of 300 Autosampler pressurizes sample to fill 1 0 mL loop with <br /> mL headspace into GC headspace sample <br /> Calibration and Quantitation Direct injections of gas Calibration standards are prepared by addition of a <br /> phase standards are gaseous spike solution to clean water Response factors <br /> used to obtain a are calculated for each level of a multi point calibration, <br /> Calibration Curve and the mean is used to calculate quantitation for each <br />' Henry's Law is used to target analyte <br /> calculate mg of gas per <br /> Liter of water <br /> Calculation requires <br /> recording total volume <br /> of serum bottle and <br /> headspace,and sample <br /> temperature <br /> Initial Calibration Curve(ICAL) Linear regression %RSD</=30%,use average RF to quantify results <br /> Lab Blanks Blank subtraction is No blank subtraction, Lab Blank must be less than the <br /> performed Reporting Limit <br /> Specified Detectors FID or ECD FID or TCD <br /> iReceiving Notes <br /> A Temperature Blank was not included with the shipment Temperature was measured on a representative <br /> sample and was not within 4t2 °C Coolant in the form of ice/blue ice was not present The discrepancy <br /> Page 2 of 15 <br />
The URL can be used to link to this page
Your browser does not support the video tag.