Laserfiche WebLink
NVATC <br /> • <br /> . A S S O C I A T E S I N C <br /> SCOPE OF WORK <br /> Field Activities <br /> ATC proposes to abandon an unused facility supply well located at the DWG facility The well <br /> is located adjacent to a staircase inside of the DWG building, the well location is shown on <br /> Figure 2 The well is located within a concrete below-grade vault below a concrete floor The <br /> vault is rectangular and has dimensions of approximately 5-feet by 5-feet by 6-feet deep The <br /> well head is mounted flush to the bottom of the vault The vault is covered with a metal cover <br /> During a previous investigation welding equipment was used to cut a hole in the immovable <br /> metal cover to allow access to the well <br /> During a previous site investigation on May 2, 2003, video well logging was performed to <br /> evaluate the condition and construction details of the on-site facility well The total depth of the <br /> facility well borehole was observed to be 133 feet below top of casing The bottom 25 feet of the <br /> borehole was open Based on observations from the bottom 25 feet of the boring, the borehole <br /> diameter was estimated to be 18 to 24 inches The well casing was constructed of steel pipe with <br /> a diameter of approximately 1 foot and extended to a depth of 108 feet from the top of casing <br /> The well was vertically perforated beginning at a depth of 67 feet below top of casing and <br /> • extended to the bottom of the casing The casing was in fair condition <br /> The well will be abandoned by filling the well casing, the filter pack, and the open space beneath <br /> the well casing with a neat cement/bentonite grout The grout will be emplaced by pumping a <br /> grout mixture into the well using a conductor pipe (tremie pipe) The conductor pipe will be <br /> extended to the bottom of the well and slowly raised toward the top of the well at a rate no faster <br /> than the grout material fills and displaces water from the well and until the well is completely <br /> filled <br /> Based upon well construction details, an estimated volume of approximately 966 to 1,223 gallons <br /> of grout will be used to abandon the facility supply well depending on the actual borehole <br /> diameter Grout volume calculations are attached Approximately 5 5 cubic yards of concrete will <br /> be required to fill the well vault <br /> Report Preparation <br /> Upon completion of the well destruction activities, a summary report will be prepared for <br /> submittal to San Joaquin County Environmental Health Department (SJCEHD) and the Regional <br /> Water Quality Control Board (RWQCB) The report will include a description of all field <br /> activities <br /> 0 W 1130991wp-wellabandonment doe 2 <br />