Laserfiche WebLink
Page 4 of 5 <br /> USC 2510,and its disclosure is strictly limited to the recipient intended by the sender of this message.This communication may <br /> contain confidential and privileged material for the sole use of the intended recipient and receipt by anyone other than the intended <br /> recipient does not constitute a loss of the confidential or privileged nature of the communications.Any review or distribution by <br /> others is strictly prohibited.ff you are not the intended recipient please contact the sender by return electronic mail and delete all <br /> copies of this communication. <br /> From: Vicki McCartney [EH] fmailto•vmccartneyCcbsicehd.com] <br /> Sent: Monday, May 13, 2013 8:50 AM <br /> To: Andrew Dorn <br /> Cc: Jenny Weese; Ray Kablanow; Nuel Henderson [EH] <br /> Subject: RE: George' Service - 1600 Durham Ferry Road,Tracy <br /> Good morning Andrew, <br /> What information do you have to demonstrate that the air sparge system is effectively cleaning up the <br /> edges of the groundwater plume? <br /> I was at the site when Del-Tech was sampling on 25 April 2013. Don Light never notified me of the <br /> sampling event and had Jenny not informed me by email on 7 April 2013, 1 would not have known to go to <br /> the site on that day. Please keep me informed of any fieldwork at this site. <br /> Thank you. <br /> Vicki McCartney, Senior REHS <br /> San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue <br /> Stockton, California 95205 <br /> Phone: (209)468-9852 <br /> Email: vmccartney0sjcehd.com <br /> ro, <br /> r. it <br /> From: Andrew Dorn rmailt0:AndreWD2gtienv.com] <br /> Sent: Friday, May 10, 2013 4:04 PM <br /> To: Vicki McCartney [EH] <br /> Cc: Jenny Weese; Ray Kablanow <br /> Subject: George' Service- 1600 Durham Ferry Road,Tracy <br /> Good Afternoon Vicki, <br /> I am contacting you in regards to the air sparge remediation system currently operating at the <br /> Georges' Service site located at 1600 Durham Ferry Road.The air sparge system is effectively <br /> cleaning up the edges of the groundwater plume (near OS-1 and OS-2) however the core of the <br /> plume has not shown a response.There is currently only one (1) air sparge well operating in the <br /> core of the plume(AS-1).We recommend that two (2)additional air sparge wells be installed <br /> within the core of the plume to accelerate remediation.The site has been granted an additional <br /> $40,000 from the Fund to be used prior to July 12013 that would cover the cost of the work. <br /> What would need to be done on our part to get these two(2) additional air sparge wells prior to <br /> July 1, 2013? <br /> 5/20/2013 <br />