Quarterly Groundwater Monitoring Report ,-'. :.� .:4TAL Hr7ALTII <br /> EMCON Associates Project: OF90-002.03 ' -`` ''f r ; L'c <br />• GENERAL. INFORMATION <br /> 1. Site: A. Teichert& Son Inc. <br /> 2. Address (Figure 1): 103 North E Street <br /> City: Stockton State: California Zip: <br /> 3. Monitoring Quarter: ❑ First ❑X Second ❑ Third ❑ Fourth Year: 1993 <br /> 4. Client Contact: George Takemori Telephone: 916 386-6916 <br /> 5. EMCON Contact: Mark Thomas Telephone: 916 928-3300 <br /> 6. tread Agency: San Joa in County Public Health Services Telephone: 209 468-3420 <br /> 7. Secondary Agency: RWQCB, Central Valley Region Telephone: 916 255-3000 <br /> BACKGROUND INFORMATION <br /> Three underground storage tanks were removed in October 1986.One underground storage tank was removed in <br /> August 1988. The tanks were not replaced.Overexcavation was completed in the vicinity of the tanks, but some impacted <br /> soil remained. Soil vapor extraction piping was installed in the overexcavation. Ten groundwater monitoring wells(MW-1 <br /> through MW-5 and MW-9 through MW-13) have been installed to date: MW-1 was damaged and MW-2 was destroyed <br /> during overexcavation activities, MW-3 through MW-5 were dry, and MW-9 was obstructed 32 feet below ground surface. <br /> A soil vapor extraction test was conducted; results indicate that soil vapor extraction is feasible for soil remediation. <br /> GROUNDWATER MONITORING DATA <br /> 1. Monitoring Date: May 10, 1993 <br /> 2. Field Measurements: See attached data forms. <br /> 3. Groundwater Flow Direction (Table 1 and Figure 1): northeast 4. Hydraulic Gradient: 0.002 <br /> 5. Comments: Direction of groundwater flow historically variable but predominantly northeast;prior to fourth quarter 1992 <br /> • monitoring event, direction of flow was southeast. <br /> GROUNDWATER ANALY7"DOX"gESU '.-S <br /> 1. Groundwater Monitoring Well Sampling Frequency (by well): All wells:quarterly. <br /> 2. Analytical Results: Summarized in Table 2, certified analytical reports attached. <br /> 3. Comments: Petroleum hydrocarbon concentrations detected are similar to historic analytical results. <br /> CONCLUSIONS/RECOMMENDATIONS/COMMENTS <br /> Continue quarterly groundwater monitoring; design, construct, and install soil vapor extraction system. <br /> Purge water generated during the quarterly sampling events will be transported to the Teichert facility at 8833 Kiefer <br /> Boulevard in Sacramento. The water will be recycled in Teichert's waste water recycle system, which is used to <br /> remove TPH and BTEX contamination from equipment rinseate. Details of the recycling system are presented in <br /> Teichert's May 14, 1993, letter to the San Joaquin County Department of Public Health Services (County). Verbal approval <br /> of the proposed disposal method was received on June 1, 1993,from Linda Turkatte,'a representative of the County. <br /> LIMITATIONS <br /> The services described in this report were performed consistent with generally accepted professional consulting <br /> principles and practices. No other warranty, express or implied, is made. These services were performed consistent <br /> with our agreement with our client. This report is solely for the use and information of our client unless otherwise <br /> noted. Any reliance on this report by a third party is at such party's sole risk. <br /> PREPARED/REVIEWED <br /> Consultant: EMCON Associates <br /> Signature: ��„�/; =7,1. e, — — Title: Pre,ec-4 sG>- Dater 7–q-3 <br /> ResponsiblePari <br /> Signature: ' Title: Date: <br />