Laserfiche WebLink
I <br /> I <br /> FIELD PRACTICES AND PROCEDURES <br /> General procedures used by Stratus in site assessments for drilling exploratory borings, <br />' collecting samples, and installing monitoring wells are described herein These general <br /> procedures are used to provide consistent and reproducible results, however, some <br /> procedure may be modified based on site conditions A California state-registered <br />' geologist supervises the following procedures <br /> PRE-FIELD WORK ACTIVITIES <br />' Health and Safety Plan <br />' Field work performed by Stratus at the site is conducted according to guidelines established <br /> in a Site Health and Safety Plan (SHSP) The SHSP is a document which describes the <br /> hazards that may be encountered in the field and specifies protective equipment, work <br />' procedures, and emergency information A copy of the SHSP is at the site and available <br /> for reference by appropriate parties during work at the site <br />' Locating Underground Utilities <br /> Prior to commencement of any work that is to be below surface grade, the location of the <br />' excavation, boring, etc , is marked with white paint as required by law An underground <br /> locating service such as Underground Service Alert (USA) is contacted The locating <br /> company contacts the owners of the various utilities in the vicinity of the site to mark the <br />' locations of their underground utilities Any invasive work 1s preceded by hand augering to <br /> a minimum depth of five feet below surface grade to avoid contact with underground <br /> utilities <br />' FIELD METHODS AND PROCEDURES <br />' Exploratory Soil Borings <br /> Soil borings will be drilled using a truck-mounted, hollow stem auger drill rig Soil <br />' samples for logging will be obtained from auger-return materials and by advancing a <br /> modified California split-spoon sampler equipped with brass or stainless steel liners into <br /> undisturbed soil beyond the tip of the auger Soils will be logged by a geologist <br />' according to the Unified Soil Classification System and standard geological techniques <br /> Drill cuttings well be screened using a portable photoionzzation detector (PID) or a flame <br /> ionization detector (FID) Exploratory soil borings not used for monitoring well <br />' installation will be backfilled to the surface with a bentonite-cement slurry pumped into <br /> the boring through a tremae pipe <br />' Soil sampling equipment will be cleaned with a detergent water solution, rinsed with <br /> clean water, and equipped with clean liners between sampling intervals Augers and <br /> samplers will be steam cleaned between each boring to reduce the possibility of cross <br />' M\Field PractieesWield P&P with CPT doc <br />