Laserfiche WebLink
Characteristics: Corrosive ( } Ignitible ( X } Toxic ( ) <br /> Reactive ( ) Volatile ( } Radioactive ( ) Biological Agent ( ) Toxicity ( } <br /> Chemical name TLV/PEL IDLH <br /> Site monitoring equipment (include calibration standards): <br /> Organic Vapor Analyzer, Calibrated to 500 PPM Hexane <br /> Heat stress conditions: Yes ( } No ( X ) <br /> Dust monitoring: Yes ( ) No ( X ) <br /> Air monitoring protocol: Monitor at the breathing zone next to the person closet to the <br /> contamination. <br /> r <br /> Conditions for suspension of operations: 100 ppm total hydrocarbons in breathing zone. <br /> 3.0 PERSONAL PROTECTION <br /> Level of protection planned: Level D personal protection equipment (PPE) includes coverall (Dry) <br /> leather/(Wet) Neoprene steel toe and shank boots, (Wet/Dry) eye protection, hard hat, and nitrile <br /> a <br /> gloves. <br /> Conditions to upgrade to level C: 100 ppm total hydrocarbons in breathing zone. <br /> '. Level C PPE includes D /Wet t vek suits with over-boots <br /> Level C contingency equipment: ( } ( ry } y <br /> . attached to the tyvek suits with duct tape, nitrile gloves, (Dry) leather/(Wet) neoprene boots with <br /> steel toe and shank, (Dry/Wet) eye protection, hard hat, and a full-face air-purifying respirator <br /> with Scott 642-OA-H cartridge filter or equivalent. <br /> ' Instruction for disposal of contaminated equipment: In approved containers only. <br /> - 4 - <br /> . <br /> — - <br />