Laserfiche WebLink
Characteristics: Corrosive ( ) Ignitible ( ) Toxic ( X } <br /> • Reactive ( ) Volatile ( ) Radioactive ( ) Biological Agent ( } Toxicity ( ) <br /> Chemical name TLV/PEL IDLH <br /> Site monitoring equipment (include calibration standards): <br /> Organic Vapor Analyzer, Calibrated to 100 PPM Hexane <br /> Heat stress conditions: Yes ( } No (X } <br /> Dust monitoring: Yes ( ) No ( X ) <br /> Air monitoring protocol: Monitor at the breathing zone next to the person closet to the <br /> contamination. <br /> Conditions for suspension of operations: 100 ppm total hydrocarbons <br /> 3.0 PERSONAL PROTECTION <br /> Level of protection planned: Level D personal protection equipment (PPE) includes coverall, <br /> (Dry) leather/(Wet) Neoprene steel toe and shank boots, (Wet/Dry) eye protection, hard hat, and <br /> nitrile gloves. <br /> Conditions to upgrade to level C: 100 ppm total hydrocarbons <br /> Level C contingency equipment: Level C (PPE) includes (Dry/Wet) tyvek suits with over-boots <br /> attached to the tyvek suits with duct tape, nitrile gloves, (Dry) leather/(Wet) neoprene boots with <br /> steel toe and shank, (Dry/Wet) eye protection, hard hat, and a full-face air-purifying respirator with <br /> Scott 642-OA-H cartridge filter or equivalent. <br /> Instruction for disposal of contaminated equipment: In approved containers only. <br /> • - 4 - <br />