My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
K
>
KASSON
>
23500
>
2800 - Aboveground Petroleum Storage Program
>
PR0528391
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/21/2019 2:56:55 PM
Creation date
7/10/2019 9:50:44 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0528391
PE
2832
FACILITY_ID
FA0007158
FACILITY_NAME
CDCR-DEUEL VOCATIONAL INSTITUTION
STREET_NUMBER
23500
STREET_NAME
KASSON
STREET_TYPE
Rd
City
Tracy
Zip
95304
APN
23912001
CURRENT_STATUS
01
SITE_LOCATION
23500 Kasson Rd
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
FRuiz
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
56
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORNIA � 2 DEPARTMENT OF CORRECTIONS AND <br /> REHABILITATION <br /> . SERVICE REQUEST <br /> CDCR 995 (5/08) PAGE _1 OF 1 <br /> INSTRUCTIONS <br /> This request is to be submitted by institutions when in need of assistance for complex technical issues in which professional Architectural and Engineering <br /> solutions are necessary. Submit the following to the Office of Facilities Planning Construction and Management, Division of Planning , Acquisition and Design , Attn : <br /> Design Services <br /> 1 . Submit sketches as necessary. <br /> 2 . Identify the problem . Indicate what is to be accomplished . <br /> 3. The solution : Describe, in detail , the recommended change or changes that will be made as applicable . <br /> INSTITUTION DATE <br /> DEUEL VOCATIONAL INSTITUTION (DVI ) & I 7- 19 <br /> PROJECT <br /> SPILL PREVENTION , CONTROL AND COUNTERMEASURE PLAN (SPCC) UPDATING WITH 3 (THREE) AIR COMPRESSORS <br /> SITE LOCATION <br /> DVI - SITE WIDE <br /> 23500 KASSON ROAD , TRACY , CA 95304 <br /> REFERENCE DATA Complete as applicable <br /> SPECIFICATION SECTION NUMBER PAGE NUMBER PARAGRAPH <br /> Table 3 ; Section 2 . 2 . 2 #79 #8 NUMBER N/A <br /> DRAWING NUMBER ENTITLED <br /> N/A Spill Prevention , Control , and Countermeasure Plan for Deuel Vocational Institution <br /> SKETCH NUMBER DATED ENTITLED <br /> N/A N/A N/A <br /> DESCRIPTION (Add extra sheets as necessary) <br /> DETAILED IDENTIFICATION OF THE PROBLEM <br /> In order to correct deficiencies as mentioned in the recent San Joaquin County audit on APSA ( violation <br /> # 301 ) and to comply with 40 CFR 112 . 5 ( a ) , facility must amend current SPCC , as follows : <br /> 1 . Table 3 must be revised reflecting current quantities and locations of bulk containers ( each equal <br /> 55 gal ) with petroleum based oil , oil products and waste oil , stored at the Vehicle Maintenance <br /> Garage , Garage Chemical Storage Area , Used Oil Storage Area , PIA Farm Equipment Storage <br /> Shed and PIA Chemical Storage Area . <br /> 2 . To revise Section 2 . 2 . 2 by addressing the fact that three 2000gallon diesel tanks at the Boiler House <br /> are permanently manifolded tanks as they are designed , installed , and operating in such manner that <br /> they function as a single storage unit manifolded together. <br /> DETAILED SOLUTION PROPOSED OR ACCOMPLISHED <br /> To review the attached revised SPCC , discuss changes and technical amendments , and re -certify it by <br /> PE . <br /> IS THE PROBLEM AN ISOLATED CASE OR CENTRAL? <br /> ❑ ISOLATED CASE ® CENTRAL <br /> SUBMIT SKETCHES AS NECESSARY AND LIST OTHER ATTACHMENTS <br /> Revised SPCC is to be e-mailed to Tai Nguyen, Civil Engineer, Design and Environmental <br /> Services & Standards Branch, Department of Corrections & Rehabilitation <br /> SUBMITTED BY: TITLE DATE <br /> Svetlana AHL AHMS 6 - 17-2019 <br /> FACILITY TELEPHONE NUMBER <br /> DEUEL VOCATIONAL INSTITUTION 209 - 8354141 EX . 5092 <br />
The URL can be used to link to this page
Your browser does not support the video tag.