My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
K
>
KASSON
>
23500
>
2800 - Aboveground Petroleum Storage Program
>
PR0528391
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/21/2019 2:56:55 PM
Creation date
7/10/2019 9:50:44 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0528391
PE
2832
FACILITY_ID
FA0007158
FACILITY_NAME
CDCR-DEUEL VOCATIONAL INSTITUTION
STREET_NUMBER
23500
STREET_NAME
KASSON
STREET_TYPE
Rd
City
Tracy
Zip
95304
APN
23912001
CURRENT_STATUS
01
SITE_LOCATION
23500 Kasson Rd
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
FRuiz
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
56
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Vi oaYl` tee � <br /> Spill Prevention, Control and Countermeasure Plan <br /> For Deuel Vocational Institution <br /> side of the tank stores 2 , 000 gallons of regular unleaded gasoline. There are two dispensers <br /> which are used to dispense the fuel . The dispensers require fuel keys for operation to prevent <br /> unauthorized activation. Piping for tank filling and for connection to dispensers is single-wall <br /> aboveground steel pipe . The AST is mounted on a concrete pad approximately 6 feet from the <br /> street curb and gutter. Approximately 25 feet north of the AST is a storm drain opening located <br /> within the street gutter. A second storm drain inlet is located in the street between the fueling <br /> station and the vehicle maintenance garage . <br /> 2 .2 .2 Boiler House Emergency Generator and temporary rented air compressor. <br /> The Boiler House is located east of the inmate housing area and north of the fueling station . Next <br /> to the Boiler House are an emergency generator and three 2 , 000- gallon ASTs for diesel fuel . The <br /> emergency generator provides standby electrical generation for the entire DVI facility when the <br /> electrical substation is off line, except for those areas with their own emergency generator. The <br /> ASTs are permanently manifolded together, being designed and installed to operate as a single <br /> storage unit with total capacity of 6 , 000 gallons of diesel fuel . Each tank is double-wall steel <br /> tank with concrete insulation. Tanks are mounted on concrete pads within a gravel area . Piping <br /> between the generator and storage tanks is single-wall steel . The piping is a combination of <br /> aboveground and underground piping, with the underground portion wrapped for corrosion <br /> protection. A storm drain inlet is located in the street gutter approximately 3 feet north of the <br /> tanks . There is also portable rental air compressor with 63 gallon diesel tank made of high <br /> density polyethylene . Compressor is placed on a collapsible spill berm of sufficient capacity, on <br /> a pavement, outside the Boiler house, of the West side, . The closest storm drain inlet is located <br /> about 40 feet away to the North . <br /> 2 .2 .3 Water Treatment (RO) Plant <br /> The water treatment plant is located south of the inmate housing area and contains an emergency <br /> generator with integral 150-gallon belly tank (day tank) and 2 , 000-galllon external AST for <br /> diesel fuel . The day tank is a double-wall steel tank within the generator package. The external <br /> tank is a double-wall steel tank with concrete insulation and is located within a concrete, <br /> secondary containment berm . Piping between the generator and external fuel tank is double-wall, <br /> with steel internal pipe and plastic external pipe . The piping runs underground between the <br /> storage tank and generator package . The containment berm around the external fuel tank is <br /> exposed to rainfall and contains a sump and drain valve to allow inspection of accumulated water <br /> prior to discharge to the grass - covered hillside west of the water treatment plant . The generator <br /> and external fuel tank are new and are located on a paved area. <br /> There are two (2) chemical storage buildings with built-in secondary containments placed on a <br /> paved area outside the Plant, East side . 55 gal steel drums with motor oil and accumulated <br /> used/waste oil are usually stored in these buildings . <br /> 2 . 2 .4 Wastewater Treatment Plant <br /> The wastewater treatment plant is located at the northeast corner of the facility and contains an <br /> emergency generator with integral 150 - gallon belly tank (day tank) and a 2 , 000 -gallon external <br /> AST for diesel fuel . The day tank is a double-wall steel tank within the generator package . The <br /> 8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.