Laserfiche WebLink
STI SP' 001 Annual l2sj2ccticn Checklist <br /> General Inspection Information ; <br /> Inspection Date: 6 '/T 12% — Retain Until Date: (36 months from inspection date) <br /> Ptitir Incr�onfin^ V4t�' /✓ / �f'f'� - /� . <br /> Inspeyc�tor Name : <br /> [Tanks Inspected (ID #'s): _ i ���'i9/Y// <br /> Inspection Guidance ; <br /> For equipment not included in this standard, follow the manufacturer recommended inspection/testing schedules and procedures . <br /> The periodic AST Inspection is intended for monitoring the external AST condition and its containment structure. This visual inspection does not require a certi ied <br /> inspector. It shall be performed by an owner's inspector who is familiar with the site and can identify changes and developing problems . <br /> Inspect the AST shell and associated piping , valves , and pumps including inspection of the coating for Paint Failure. <br /> "r Inspect: <br /> 1 . Earthen containment structures including examination for holes, washout, and cracking in addition to liner degradation and tank settling . <br /> 2. Concrete containment structures and tank foundations/supports including examination for holes, washout, settling , paint failure, in addition to examination for <br /> corrosion and leakage. <br /> 3. Steel containment structures and tank foundations/suppbrts including examination for washout, settling, cracking , and for paint failure, in addition to <br /> examination for corrosion and leakage , <br /> r inspection of cathodic protection system , if applicable, includes the wire connections for galvanic systems and visual inspection of the operational components <br /> (power switch, meters, and alarms) of impressed current systems . <br /> Remove promptly upon discovery standing water or liquid in the primary tank, secondary containment area, interstice, or spill container. Before discharge to the <br /> environment, inspect the liquid for regulated products or other contaminants and disposed of it properly. <br /> In order to comply with EPA SPCC (Spilt Prevention, Control and Countermeasure ) rules , a facility must regularly test liquid level sensing devices to ensure proper <br /> operation (40 CFR 112 . 8 (c)(8) (v)). <br /> r (") designates an item in a non-conformance status. This indicates that action is required to address a problem . <br /> r Non-conforming items important to tank or containment integrity require evaluation by an engineer experienced in AST design , a certified inspector, or a tank <br /> manufacturer who will determine the corrective action . Note the non-conformance and corresponding corrective action in the comment section. <br /> r Retain the completed checklists for 36 months. <br /> Complete this checklist on an annual basis supplemental to the owner monthly-performed inspection checklists. <br /> r Note : If a change has occurred to the tank system or containment that may affect the SPCC plan, the condition should be evaluated against the current <br /> plan requirement by a Professional Engineer knowledgeable in SPCC development and implementation, <br /> AST INSPECTION STANDARD 31 JULY 2006 <br />