My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HOFF
>
1515
>
2800 - Aboveground Petroleum Storage Program
>
PR0528646
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/10/2019 1:16:18 PM
Creation date
7/10/2019 10:59:52 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0528646
PE
2832
FACILITY_ID
FA0017929
FACILITY_NAME
SPEEDCO # 944
STREET_NUMBER
1515
STREET_NAME
HOFF
STREET_TYPE
DR
City
RIPON
Zip
95366
APN
24534026
CURRENT_STATUS
01
SITE_LOCATION
1515 HOFF DR
P_LOCATION
05
P_DISTRICT
005
QC Status
Approved
Scanner
FRuiz
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
66
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
-h <br /> J" <br /> Spill Prevention,Control,and Countermeasure Plan <br /> Love's/Speedco#944,Ripon,California <br /> Page 4of13 anteagroup <br /> 4.0 GENERAL REQUIREMENTS <br /> General requirements for SPCC Plans are set forth in 40 CFR§112.7. Specific requirements for the types of oil used <br /> and stored at the Love's/Speedco #944 facility are described in 40 CFR §112.8. Each applicable requirement is <br /> discussed in the following sections. Information is presented in the general sequence shown in 40 CFR §112.7.The <br /> locations of any items not discussed in this sequence are clearly referenced. Some elements of Sections §112.8 <br /> duplicate items from Section §112.7, in which case further discussion or reference may not be provided. <br /> 4.1 Management Commitment(40 CFR 112.7): <br /> Love's/Speedco #944 is committed to provide the necessary resources (labor, equipment, materials, and funds) <br /> necessary to fully implement this SPCC Plan. Site management's acknowledgement of this commitment appears at <br /> the beginning of the Plan. <br /> 4.2 Conformance with Requirements and Deviations [40 CFR 112.7(a)(1)-(2) and 112.6(b)(4)]: <br /> Love's/Speedco #944 is committed to conform to the requirements of the Oil Pollution Prevention rules. Any <br /> deviations from the requirements will be carried out in accordance with the procedures described at 40 CFR <br /> §112.6(b)(4), §112.7(a)(2), and §112.7(d). 40 CFR §112.7(a)(2) allows deviations from certain requirements if the <br /> facility explains the reason for the deviation in the Plan and provides environmental protection equivalent to that <br /> which is called for in the rule. §112.7(d) identifies certain requirements from which deviations are allowed only if <br /> the facility has either a §112.20 Facility Response Plan (FRP), or a Part 109 Oil Spill Contingency Plan (OSCP),which <br /> is administered by local or regional authorities. 40 CFR §112.20 requires facilities with the potential to cause <br /> substantial harm to the environment as a result of an oil spill to develop and submit to EPA a Facility Response <br /> Plan.The Love's/Speedco#944 facility does not meet the criteria required for classification under the applicability <br /> of substantial harm criteria, per 40 CFR §112,therefore,the facility is not required to develop a FRP, and a local or <br /> regional OSCP has not been formed. Refer to the signed certification form contained in Appendix G. <br /> The facility does not serve as an oil production or work-over facility (on or offshore). Therefore, the provisions of <br /> 40 CFR§112 relevant to these facilities are not applicable to this plan. <br /> 4.3 Description and Physical Layout of the Facility[40 CFR 112.7(a)(3) and 40 CFR 112.7(a)(3)(i)]: <br /> The Love's/Speedco#944 facility is located at 515 Hoff Drive, Ripon, California off of Interstate 99 at Exit 2376. It is <br /> used for providing complete oil changing services for semi-trucks.The facility has one building onsite comprised of <br /> a vehicle maintenance area and an office located inside.The vehicle maintenance consists of three lubrication bays <br /> and two tire service bays. The hours of operation at this location are 8:00 am to 8:00 pm, Saturday and Sunday, <br /> and 7:00 AM to 10:00 PM Monday through Friday. Personnel at this location include a general manager, assistant <br /> managers,crew chief,technicians,and clerks.The location is always manned during hours of operation. <br /> Seven (7) bulk (>55 gallon) oil storage tanks are located within the interior of the Facility. The bulk oil tanks are <br /> also referred to herein as aboveground storage tanks (ASTs). Oil-containing products are stored and handled <br /> throughout the Facility. The Facility's total oil-storage capacity is approximately 37,900 gallons. The locations of <br /> bulk oil storage tanks, drainage features, and other important site features are depicted in Figure 2 (Facility <br /> Diagram-Interior). <br /> An oil and water separating unit is used to treat wastewater at the Facility, prior to discharge to a municipal <br /> treatment system. <br />
The URL can be used to link to this page
Your browser does not support the video tag.