1515
>
2800 - Aboveground Petroleum Storage Program
>
PR0528646
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/10/2019 1:16:18 PM
Creation date
7/10/2019 10:59:52 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0528646
PE
2832
FACILITY_ID
FA0017929
FACILITY_NAME
SPEEDCO # 944
STREET_NUMBER
1515
STREET_NAME
HOFF
STREET_TYPE
DR
City
RIPON
Zip
95366
APN
24534026
CURRENT_STATUS
01
SITE_LOCATION
1515 HOFF DR
P_LOCATION
05
P_DISTRICT
005
QC Status
Approved
Scanner
FRuiz
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
66
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Monthly SPCC Inspection Checklist <br /> Item Inspection <br /> No. Item Task N/A Yes No Comments <br /> 3.4 Overfill If overfill valve is <br /> Equipment equipped with a <br /> mechanical test <br /> mechanism,actuate <br /> the mechanism to <br /> confirm operation. <br /> 3.5 Piping Check for leaks, <br /> Connections corrosion and damage <br /> 4.0 Tank Attachments and Appurtenances <br /> 4.1 Ladder and Secure with no sign of <br /> Platform severe corrosion or <br /> Structure damage? <br /> 5.0 Other Equipment/Conditions <br /> 5.1 Security lighting,fencing, door locks,cap <br /> locks,etc.are operational? <br /> 5.2 Oil-filled transformers are not leaking? <br /> 5.3 Other oil-filled equipment is working <br /> properly and do not show signs of leaking? <br /> 5.4 Spill kits are properly located and stocked? x <br /> 5.5 Were corrective actions from previous <br /> inspection completed? <br /> Additional Comments: <br /> Inspection Guidance: <br /> • For equipment not included in this Standard,follow the manufacturer recommended inspection/testing schedules <br /> and procedures. <br /> • The periodic AST Inspections intended for monitoring the external AST condition and its containment structure.This <br /> visual inspection does not require a Certified Inspector.It shall be performed by an owner's inspector who is familiar <br /> with the site and can identify changes and developing problems. <br /> • Upon discovery of water in the primary tank,secondary containment area,interstice,or spill container,remove <br /> promptly or take other corrective action.Before discharge to the environment,inspect the liquid for regulated <br /> products or other contaminants and disposed of it properly. <br /> • (*)designates an item in a non-conformance status.This indicates that action is required to address a problem. <br /> • Non-conforming items important to tank or containment integrity require evaluation by an engineer experienced in <br /> AST design,a Certified Inspector,or a tank manufacturer who will determine the corrective action. <br /> • Retain the completed checklist for 36 months. <br /> • Form based on STI SP001 Monthly Inspection Checklist,September 2011. <br /> Page 2 of 2 <br />