My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HOFF
>
1515
>
2800 - Aboveground Petroleum Storage Program
>
PR0528646
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/10/2019 1:16:18 PM
Creation date
7/10/2019 10:59:52 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0528646
PE
2832
FACILITY_ID
FA0017929
FACILITY_NAME
SPEEDCO # 944
STREET_NUMBER
1515
STREET_NAME
HOFF
STREET_TYPE
DR
City
RIPON
Zip
95366
APN
24534026
CURRENT_STATUS
01
SITE_LOCATION
1515 HOFF DR
P_LOCATION
05
P_DISTRICT
005
QC Status
Approved
Scanner
FRuiz
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
66
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
S b N J 0 A Q U I N Environmental Health Department <br /> COUNTY <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: Date: <br /> SPEEDCO#944 1515 HOFF DR, RIPON June 10, 2019 <br /> Other Violations <br /> 4030 See below Unlisted Operations/Maintenance violation ❑V ❑R ❑COS <br /> 4040 See below Unlisted Release/Leaks/Spills violation ❑V ❑R ❑COS <br /> 4050 See below Unlisted Abandonment/Illegal Disposal/Unauthorized Treatment violation ❑V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 603 CFR 112.7(a)(3)Failed to adequately describe the physical layout of the facility in the Plan. <br /> The facility diagram was missing the storage area of portable containers. The Spill Prevention, Control, and <br /> Countermeasure(SPCC)Plan shall include a facility diagram which must mark the location and contents of each <br /> fixed storage container and the storage area where mobile or portable containers are located. It must identify the <br /> location of and mark as"exempt'underground tanks. It must also include all transfer stations and connecting pipes, <br /> including intra-facility gathering lines. Immediately update the facility diagram to include all of the required <br /> information. Submit a legible copy of the updated facility diagram to the EHD for review. <br /> This is a Class II violation. <br /> 609 CFR 112.7(a)(3vi), 112.7(a4)Plan failed to adequately contain procedures for reporting a discharge. <br /> The Spill Prevention, Control, and Countermeasure(SPCC)Plan does not provide information and procedures to <br /> enable a person to adequately report a discharge. The phone number for the SJC Environmental Health Department <br /> (209-468-3420)and the Facility Response Coordinator phone number are missing. If a response plan was not <br /> submitted to the Regional Administrator,this information must be included in the SPCC Plan. Immediately ensure <br /> that the SPCC Plan includes this information and submit a copy of the revision to the EHD. <br /> This is a minor violation. <br /> 622 CFR 112.7(f)(3) Failure to conduct complete annual discharge prevention briefings for oil-handling personnel. <br /> Discharge prevention briefings are not scheduled at least once a year. The last training for discharge prevention <br /> was 3/21/2018. Discharge prevention briefings for oil handling personnel must be scheduled and conducted at least <br /> once a year to assure adequate understanding of the SPCC Plan for that facility. Such briefings must highlight and <br /> describe known discharges or failures, malfunctioning components, and any recently developed precautionary <br /> measures. Immediately schedule and conduct a discharge prevention briefing, ensure that they are scheduled and <br /> conducted at least once a year. <br /> This is a minor violation. <br /> FA0017929 PRO528646 SCO01 06/10/2019 <br /> EHD 28-01 Rev.09/27/2018 Page 4 of 5 Aboveground Petroleum Storage Act OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.