Laserfiche WebLink
SAN J O A Q U I N Environmental Health Department <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: FacOity AeNmss. pate. <br /> LDS-STOCK I ON R ISI OPS STOREHOUSE 39': LOON IS R,7. STOCKTON June 25.2019 <br /> SUMMARY OF VIOLATIONS <br /> (M-ASS 1,CL 89 It,or MINOn-Nalco to eomphy) <br /> Items Remarks <br /> 609 CFR 112.7(a)(3vi), 112.7(e4)Plan failed to adequately contain procedures for reposing a discharge. <br /> The Spill Prevention,Control,and Countermeasure(SPCC)Plan does not provide information and procedures to <br /> enable a person to adequately report a discharge-The name and phone number ofthe California Office of Emergecy <br /> Services State Warning Center was not in the SPCC plan. Its response plan was not submitted to the Regional <br /> Administrator,this information must be included in the SPCC Plan. Immediately amend the SPCC Plan to include <br /> this information and submit a copy of revision to the EHD. <br /> This is a minor violation. <br /> 710/ CFR 112.8(c)(6)Plan failed to adequately discuss procedures to test or inspect each container for integrity. <br /> V The SPCC plan does not address or determine in accordance with industry standards,the appropriate qualifications <br /> for personnel performing tests and inspections,the frequency and type of testing and inspections,which take into <br /> Gaccount container size,configuration,and design. <br /> The interstitial space of the double walled tank is not being inspected.EPA has determined that the inspection of the <br /> Interstitial for double walled tanks is the equivalent to inspecting the outside of the container for signs of deterioration, <br /> discharges,or accumulation of oil inside diked areas <br /> Test or inspect each aboveground container for integrity on a regular schedule and whenever you make material <br /> repairs.You must determine,in accordance with industry standards,the appropriate qualifications for personnel <br /> performing tests and inspections,the frequency and type of testing and inspections,which take into account container <br /> size,configuration,and design(such as containers that are:shop-built,field-erected,skid-mounted,elevated, <br /> equipped with a liner,double-walled,or partially buried).Examples of these integrity tests include,but are no(limited <br /> to:visual inspection,hydrostatic testing,radiographic testing,ultrasonic testing,acoustic emissions testing,or other <br /> systems of non-destruclive,testing. You must keep comparison records and you must also Inspect the container's <br /> supports and foundations.In addition,you must frequently inspect the outside of the container for signs of <br /> deterioration,discharges,or accumulation of oil inside diked areas.Records of inspections and tests kept under usual <br /> and customary business practices satisfy the recordkeeping requirements of this paragraph. <br /> The SPCC plan should indicate what industry standard the tanks fall under and determine,in accordance with industry <br /> standards,the appropriate qualifications for personnel performing tests and inspections,the frequency and type of <br /> testing and inspections,which take into account container size, conflgum&on,and design. <br /> This is a repeat violation,Class Il. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork by July 25,2019 <br /> FAMISM0 PRaaoaSuS Seam Seaso r, <br /> EHo M-01 on.M74IM6 Page Sas M .� dPelmkum cors,eat an <br /> 1868 E.Hazelton Avenue I Stockton,California 95205 1 T 209468-34201 F 209 464-0138 1 www_sjcehd.com <br />