My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SITE INFORMATION AND CORRESPONDENCE
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EIGHT MILE
>
15135
>
2900 - Site Mitigation Program
>
PR0518132
>
SITE INFORMATION AND CORRESPONDENCE
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/10/2019 1:23:26 PM
Creation date
7/10/2019 11:39:29 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
SITE INFORMATION AND CORRESPONDENCE
RECORD_ID
PR0518132
PE
2960
FACILITY_ID
FA0013716
FACILITY_NAME
H & H MARINA
STREET_NUMBER
15135
STREET_NAME
EIGHT MILE
STREET_TYPE
RD
City
STOCKTON
Zip
95219
APN
06908021
CURRENT_STATUS
01
SITE_LOCATION
15135 EIGHT MILE RD
P_LOCATION
01
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
291
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ORDER NO. 5-00-119 • . 2 <br /> ATTACHMENT B <br /> MONITORING AND REPORTING PROGRAM <br /> GENERAL ORDER FOR DISCHARGE TO <br /> SURFACE WATERS OF GROUND WATER <br /> FROM CLEANUP OF PETROLEUM FUEL POLLUTION <br /> EFFLUENT MONITORING <br /> Effluent samples shall be collected from the last connection through which wastes can be admitted into . <br /> the outfall. Effluent samples should be representative of the volume and nature of the discharge. Time <br /> and specific location of collection of the grab sample shall be recorded. The following shall constitute <br /> the effluent monitoring program: <br /> Type of Sampling <br /> Constituents Units Sample Frequency <br /> Flow rngd continuous Monthly <br /> Specific Conductivity µmhos/cm Grab Monthly <br /> pH pH units Grab Monthly <br /> Temperature OF Grab Monthly <br /> Total Dissolved Solids mg/l ' Grab Monthly <br /> Total Petroleum Hydrocarbons mg/l Grab Monthly** <br /> (Gasoline, diesel,motor oil) <br /> Benne 4/1 Grab Monthly* <br /> Toluene M/1Grab Monthly** <br /> Grab Monthly** <br /> Ethylbenzene µg/1 Grab Monthly** <br /> Xylene (Total) n/in/l Grab Monthly** <br /> MTBE µ� <br /> Lead (total)* 49/1 Grab Monthly** <br /> Bioassay*** % Survival Grab Quarterly <br /> Methanol µg/1 Grab Monthly'"* <br /> Grab Monthly** <br /> Ethanol µB1 <br /> Tertiary Butyl Alcohol(TBA) µ Grab Monthly**gll Grab Monthly** <br /> .Di.Isopropyl Ether(RIPE) µg/1 Grab Monthly** <br /> Ethyl Tertiary Butyl Ether(ETBE) µS/1 Grab Monthly** <br /> Tertiary Amyl Methyl Ether 119/1 <br /> (TAME) <br /> * If lead is not detected in the fust 2 sampling events,then testing may be discontinued thereafter. <br /> *• 1) Analyses shall be conducted weekly for four consecutive weeks following initial discharge from the trea na <br /> system, 2)If any sample.shows detectable TPH,Benzene,Toluene,Ethylbenzeae,Xylene,MTBE or other oxyg <br /> the Discharger shall immediately resample and reanalyze the effluent for the detected constiment(s),and shall continue <br /> sampling the effluent on a weekly basis until the constiment(s) concentrations are below permitted levels.3) If three <br /> consecutive monthly sampling events result in non-detectable concentration, at appropriate detection limits, then the <br /> sampling frequency shall be reduced to'Quarterly. 4) If a detectable concentration is determined to be present in the <br /> wastewater the frequency will revert back to monthly. 5) If a constituent.is not present in the influent sample,then the . <br /> testing for that constituent maybe discontinued until detected in the influent: <br /> +** The acute bioassays samples shall be analyzed using EPA/600/4-90l027F, or later amendment with Board staff <br /> approval. Temperature and pH shall be recorded at the time of bioassay sample collection. Test species shall be <br /> fathead minnows(Pimephales promelas),with no pH adjustment unless approved by the Executive Officer. <br />
The URL can be used to link to this page
Your browser does not support the video tag.