estimated using, the dLpth-til-Nvater measurements collected on December 31, 1997 indicated that groundwater
<br /> flow at the, site was generally Lonsistent with the estimated flow on September 18, 1997
<br /> On March 217 1998 Condor personnel wcre on site to conduct quarterly groundwater monitoring t aboratory
<br /> analyses of groundwater samples collected from the site monitor wells indicated that BTEX, fPH-G and the
<br /> selee.ted gasoline oxygenates/additives were not detected at or above the laboratory reported detection limits in
<br /> the Sample collee,ted from MW-1 Ethanol, tertiary-butanol, DfPF F'TBh, and TAME were not detected at or
<br /> above the laboratory reported detection limas in any of the, groundwater samples Detection limits for the
<br /> analysis of the samples collected from MW-2 and MW-3 were raised, however, due to relatively high
<br /> concentrations of M FBF in the samples collected From those wells (as described below) Benzene and ]'PH-G
<br /> were not detected at or above raised detection limits and low concentrations of TEX constituents were detected in
<br /> the sample. collected from MW-2 ;MTBE was detected at 1 10,000 pg/l in the MW-2 sample BTEX and TPH-G
<br /> were not detected at or above the laboratory reported detection limas in the sample collected from MW-3 MTBE
<br /> was detected at 1,900 µg/1 in the MW-3 sample TPH-G and 131-EX constituents were detected in the sample
<br /> collected from MW-4 VITBF was not detected at or above the laboratory reported detection limit in the MW-4
<br /> sample No floating product, sheen, or petroleum hydrocarbon odor was noted in the monitor wells
<br /> Laboratory analytical results of the groundwater samples for the first quarter, I998, monitoring event were
<br /> generally consistent with historical quarterly groundwater analytical data MTBE concentrations in samples
<br /> from MW-2, however, increased by more than two orders of magnitude during the three sampling events
<br /> conducted at the site
<br /> Groundwater elevation measurements collected at the site on March 27, 1998, indicated that the average depth to
<br /> groundwater was approximately S feet bgs The average depth to water at the site increased by approximately 1
<br /> foot between December 31, 1997 and March 27, 1998 Groundwater elevation contours estimated using the
<br /> depth-to-water measurements collected on March 27, 1998, indicated that groundwater gradient at the site is
<br /> generally consistent with the estimated gradient on September 18, 1997, and December 31, 1997
<br /> I In a telephone conversation on March 23, 1998, Mr Ronald Rowe of the San Joaquin County Public Health
<br /> Services/Environmental Health Department (PIIS/1-HD) indicated that based on his review of the report dated
<br /> December 1 ], 1997 (referenced above), he was requesting that quarterly groundwater monitoring continue at the
<br /> I site Furthermore, he requested that a work plan be prepared for conducting quarterly surface water sampling
<br /> and additional investigation of the gasoline oxygenate/additive plume to the east of monitor well MW-2 Condor
<br /> subsequently prepared the Work Plan Additional Soil and Groundwater Investigation / Surface Water
<br /> Sampling, dated May 27, 1998 In a faxed note dated June 1, 1998, Mr Rowe approved the work plan with the
<br /> stipulation that a work plan addendum be prepared describing installation of additional borings to those proposed
<br /> in the work plan and grab sampling of the Herman & Helen's Marina drinking water source Condor
<br /> subsequently prepared the Work Plan Addendum, dated July 9, 1998 In a fax dated July 27, 1998, Mr Ron
<br /> Rowe approved the work plan addendum adding that both the facility pre-treated drinking water and the post-
<br /> treatment water should be sampled and analyzed by appropriate methods
<br /> On June 26, 1998, a Condor representative was on site to conduct quarterly groundwater monitoring Laboratory
<br /> analyses of groundwater samples collected from the site monitor wells indicated that BTEX, TPH-G and the
<br /> selected gasoline oxygenates/additives were not detected at or above the laboratory reported detection limits in
<br /> the sample collected from MW-1 Ethanol, tertiary-butanol, DIPS, and ETBE were not detected at or above the
<br /> laboratory reported detection limits in any of the groundwater samples TAME was detected in the samples
<br /> collected from MW-2 and MW-3 MTBE was detected in the samples collected from MW-2, MW-3, and MW-4
<br /> BTEX and TPH-G were not detected at or above raised laboratory detection limits in the samples collected from
<br /> • MW-2 and MW-3 Relatively low concentrations of benzene, ethyl benzene, total xylenes, and TPH-G were
<br /> detected in the sample collected from MW-4 Toluene was not detected at or above a raised laboratory detection
<br /> limit in the sample collected from this well Floating product or sheens were not observed in the groundwater
<br />
|