Laserfiche WebLink
i <br /> sample collected from MW-2 Benzene, xylene, MTBE, tertiary butanol, and TAME were detected in the <br /> groundwater sample collected from MW-2 (0 4, 1 5, 550, 72 and 3 6 4g11, respectively) BTEX and TPH-G were <br /> not detected at or above the laboratory reported detection limit to the groundwater sample collected from MW-3 <br />' MTBE was detected to the groundwater sample collected from MW3 (7 9 µg11) BTEX, MTBE and TPH-G were <br /> detected in the groundwater sample collected from MW-4 (1 6 µg/l, 0 4 µg/l, 2 0 µg/l, 22 µg/l, 14 µg/l, and 0 8 <br /> mg/l, respectively) Laboratory analytical results for the September 18, 1997 sampling event are presented below <br /> Iin Table B 6 <br /> ITABLE B.6 <br /> Groundwater Sample Analytical Results— September 18, 1997 <br /> B T E X Gasoline TPH-G TEPH <br /> Additives <br /> I Oxygenates <br /> Kerosene Diesel Motor Oil <br />' Detection 0 3 0 3 0 3 0 6 10 0 05 005 0 05 0 5 <br /> Limits µg/I µg/1 µg/1 µg/1 µg/1 mg/1 mg/i mg/1 mg/1 <br /> Sample f D <br /> MWl-9/18/97 ND ND NO ND ND ND ND ND NO <br /> MW2-9/18/97 0 4 ND NO 15 550(MTBE) NO ND ND NO <br /> 72(tertiary- <br /> butanol) <br /> 3 6(TAME) <br /> MW3-9/18/97 ND ND ND ND 7 9(MTBE) ND NO ND NO <br />' MW4-9/18/97 16 0 4 2 0 22 14(MTBE) 0 08 NO ND NO <br /> Un t Couverslons. Analytical <br />' p&g parts per bdl—(pph) BTEX-benzene toluene ethyl benzene,and xylene <br /> mg/kg_parts per million(ppm) TEPH total petrolc m hydrocarbons,quantified as kerosene,diesel and motor oil <br /> TPH-G total petroleum hydrocarbons,quantified as gasoline <br /> MT13E-methyl tint butyl ether <br /> TAME-tertiary amyl methyl ether <br /> ND-none detected at or above laboratory detection bmim <br /> =other gasohine addravesioxygeaatcs ND <br /> On December 31, 1997, Condor personnel were on site to conduct quarterly groundwater monitoring Laboratory <br />' analyses of groundwater samples indicated that BTEX, TPH-G, and the selected gasoline oxygenates/additives <br /> were not detected at or above the laboratory reported detection limits in the sample collected from MW-1 <br /> Ethanol, DIPE, and ETBE were not detected at or above the laboratory reported detection limits in any of the <br />' groundwater samples BTEX, TPH-G, and tertiary butanol were not detected at or above the laboratory reported <br /> detection llanits In the sample collected from MW-3 MTBE and TAME were detected to the sample collected <br /> from MW-3 Low concentrations of BTEX constituents and TPH-G were detected in the samples collected from <br />' MW-2 and MW-4 MTBE was detected in.MW-4 MTBE, tertiary butanol, and TAME were detected in MW-2 <br /> No floating product, sheen, or petroleum hydrocarbon odor was noted in the monitor wells Full evaluation of <br /> intrinsic bioremediation parameters was not conducted because additional monitoring was necessary to evaluate <br />' the potential for intrinsic bioremediation at the site <br /> Groundwater elevation measurements collected at the site monitor wells on December 31, 1997, indicated that <br /> the average depth from the ground surface to groundwater was approximately 4 feet The average depth to water <br /> at the site decreased by approximately 2 feet between September 18, 1997 and December 31, 1997 Groundwater <br /> I <br />