System Monitoring (January - October 1994) <br /> 141 N. EI Dorado Avenue <br /> Sod Vent System with Granulated Activated Carbon <br /> Air Permit to Operate No: N-1132-2-0 <br /> Authority to Construct No: N-1133-2-1 <br /> Air Permit to Operate Conditions Max Airffowrate = 200 CFM, Max TPH cont = 32 ppmv (gasoline) or 168 ppmv {methane) <br /> Date Time Wells Fresh Soil Vapor Temp Pitot Tube Airflow Airflow oneentration Benzene TPH TPH TPH Cumul. TPH <br /> Open to Air Valves Extraction Velocity (avg ) (avg I Influent Influent Effluent Extraction Extraction Extraction <br /> Venting Condition Vacuum Pressure (4 in pipe) (ppmv) fppmv) (ppmv) (ppmv) (lbs/day) fibs/day) estimate Comments <br /> (in H2O) (da F) (in H20) (ACFM) (SCFM) ID, ava ) (LAB) (LAB) (FAD) (FID) (LAB) (lbs-LAB) <br /> 1/7/94930 VEW-1,2,3,4 closed -45 82 Oil 117 114 140 99 0 038 30 1167 <br /> 1/27/94 VEW-1 2,3,4 closed System shut down (1127194) <br /> 3/17194 13 45 VEW-1,2,3,4 closed -40 75 015 141 140 207 110 ND(<0 18) 0 93 49 1167' Restarted system (3/17/94) <br /> after GAC replacement <br /> 4/5/94 11 15 VEW-1,2,4 closed -40 103 015 140 132 91 85 ND(<0 16) 0 3 9 36 1247 <br /> 4/19/94 15 30 VEW-1,2,3,4 closed -40 109 016 145 135 160 98 69 <br /> 5/3/94 11 50 VEW-1,2,3,4 closed -45 104 014 135 127 30 Be 019 1 1 2 28 1337 <br /> 5/17/94 13 45 VEW-1 2,3,4 closed -43 101 0 15 139 127 $0 57 ND(<0 08) 5 8 33 23 1373 <br /> 6/1194 1100 VEW-1,2,3,4 closed -43 117 014 137 126 44 51 041 1 2 1 8 2 1 1406 <br /> 6/13/94830 VEW-1 2,3,4 closed -43 117 014 137 126 40 1 B System Shutdown <br /> 6/13 - 7/8/94 <br /> ( -7/8 ) for remediation <br /> system modification <br /> 7/11/94945 [E:W <br /> 12 3 4,Mw 3 vrtrary ops+ -31 74 06 153 152 56 24 ND(<0 16) 7 27 1 2 14060 <br /> 8/23/94 15 30 1 2 3 4 MW-3 panoliv open -15 83 024 97 95 40 45 ND(<O 016) 7 1 2 14 1462 <br /> 9/20194 10 55 1 2 3 4 MW 3 closed -35 114 016 146 135 38 45 ND(<O 016) 3 1 6 19 1508 <br /> 10/4/94 15 40 1 2 3 4 MW 3 closed -35 106 016 145 136 26 34 ND(<0 018) 7 11 15 1532 <br /> Notes <br /> �. System consists of one regenerative blower with 5 hp motor and two 2000 Ib GAC units in series (Unit 1 and Unit 2) <br /> System start-up was conducted by Aegis Environmental (now Fugro West) on 6123/93 <br /> avg = average of three sets of measurements collected at 15 minute intervals (as required by air permit) <br /> GAC = granular activated carbon <br /> Airflow measured between Unit 1 and Unrt 2 except on 7111/94 and 8123/94 Airffow measured at the vent well manifold on 7/11/94 and 8/23194 <br /> Influent = prior to Unrt 1/soil vent blower discharge <br /> Effluent = Unrt 2 (atmospheric discharge) <br /> TPH = total petroleum hydrocarbons as gasoline <br /> ppmv = parts per million by volume <br /> FiD -field measurement from flame ionization detector calibrated to hexane(Model Century OVA 128 by Foxboro Company) <br /> LAB = laboratory analysis <br /> ND = not detected at indicated reporting limit <br /> ACFM = actual cubic feet per minute <br /> SCFM = standard cubic feet per minute (14 7 PSI and 70 deg F) <br /> PSI = pounds/square inch <br /> See attached extraction rate calculation <br /> Cumulative extraction is calculated by averaging extraction rates for consecutive sampling events and summing up previous total <br /> 'Cumulative TPH extraction calculations do not Include TPH extraction between 1/7-1/27 & 718-7111194 <br /> t i <br />