SENT BY: �7- 2-96 : 3:OOPM CLAYTON PLEAI'NITON- 209 937 8822:# 5 <br /> Clayton <br /> TNVIRONMENTAI <br /> CONSULIANIS <br /> Pago 4 of 17 <br /> Analytical Results <br /> for <br /> Clayton Environmental Consultants, Inc . <br /> Client Reference: 70121 . 00 <br /> Clayton Project No. 96063 . 35 <br /> Sample Identification: M-1 Date Sampled: 06/24/96 <br /> Lab Number: 9606335-01C Date Received: 06/24/96 <br /> Sample Matrix/Media: WATER Date Prepared: 06/25/96 <br /> Preparation Method: EPA 5030A Date Analyzed: 06/25/96 <br /> Method Reference: EPA 8260A Analyst: JP . <br /> Limit <br /> of <br /> Concentration Detection <br /> Analyte GAS # (ug/L) (ug/L) <br /> Volatile Organic Comyounds (Continued) <br /> 1., 2, 3-Trichloropropane 96-18-4 ND 5 <br /> 1 , 2 , 4-Trimethylbenzene 95-63-6 ND 5 <br /> 1 , 3 . 5-Trimethylbenzene 108-67-8 NO 5 <br /> Vinyl acetate 106-05-4 NO 10 <br /> Vinyl chloride 75-01-4 ND 5 <br /> o-Xylene 95-47-6 ND 5 <br /> p.m-Xylenes -- NO 5 <br /> Surrogates - Recovery OC Limits A) <br /> 4-Bromofluorobenzene _ 460-00-4 93 86 - 115 <br /> Dibromofluoromethane 1868- 53-7 101 86 - 118 <br /> 1, 2-Dichloroethane-d4 17060-07-0 96 76 - 114 <br /> Toluonc-d8 2037-26-5 104 88 = _110 <br /> NO: Not detected at or above limit of detection <br /> - - . Information not available ,or not applicable <br />