s Jt'V LY- --N 4:u;jrm : C;LAT 1 ON rLCA-Sk�NTON- 208 037 8822;# 3 <br /> Clayton <br /> t•NVIKUNMEN7g1, <br /> _ CONSut.taNlS <br /> Analytical Results Page 15 of 17 ' <br /> for <br /> Clayton Environmental Consultants, Inc. <br /> Client Reference: 70127.00 <br /> Clayton Project No. 96063.35 <br /> Sample Identification: M-2 Date Sampled: 06/24/96 <br /> Lab Number: 9606335-02 Date Received: 06/24/96 <br /> Sample Matrix/Media: WATER Date Extracted: 06/24/96 <br /> Method <br /> Detection Date Date Prep Method <br /> Analyte Concentration Limit Units Prepared Analyzed Method Reference <br /> TPH-D 410 a 50 ug/L 06/24/96 06/26/96 EPA 3510 EPA 8015* <br /> TPH-G 940 b 50 ug/L 06/27/96 06/27/96 EPA 5030 EPA 8015 <br /> TPH-0 .200 200 ug/L 06/24/96 06/26/96 EPA 3580 EPA 8015* <br /> • I <br /> NO: Not detected at or above limit of detection <br /> --. Information not available or not applicable <br /> TPH-D = Extractableetroleum hydrocarbons ydrocarbone frorn C10 to C20 quantitated as diesel. , <br /> TPH-G = Volatile petroleum hydrocarbons from C4 to C12 quantitated as gasoline. <br /> " Modified <br /> TPH-0 = Extractable petroleum hydrocarbons from C20 to C42 quantitated as motor oil. <br /> a Unidentifiable hydrocarbons do not match the typical diesel pattern. <br /> Some portion of the TPH result may be attributed to the presence of gasoline. <br /> b Purgeable hydrocarbons quantitated as gasoline do not match typical gasolino pattern. <br /> I <br />} a <br /> I <br /> j <br /> i <br /> k <br />