My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHEROKEE
>
900
>
2300 - Underground Storage Tank Program
>
PR0231841
>
COMPLIANCE INFO 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/25/2019 4:45:17 PM
Creation date
7/11/2019 1:28:39 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2018
RECORD_ID
PR0231841
PE
2361
FACILITY_ID
FA0000556
FACILITY_NAME
ARCO CHEROKEE GAS & MART*
STREET_NUMBER
900
Direction
S
STREET_NAME
CHEROKEE
STREET_TYPE
LN
City
LODI
Zip
95240
APN
04742007
CURRENT_STATUS
01
SITE_LOCATION
900 S CHEROKEE LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN J O A Y U I N Environmental Health Department <br /> —00U IJ'F <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: T�teCHEROKEE LANE SERVICE STATION* 900 S CHEROKEE LN, LODI ber 29, 2018 <br /> Item# Remarks <br /> 103 HSC 25292.2,25299.30 Failure to submit and maintain complete and current financial responsibility documents. <br /> Current Financial responsibility documents have not been submitted to the EHD. Financial responsibility documents <br /> were last signed on 6/20/2017.Current financial responsibility documents are required to be submitted annually. <br /> Immediately log into the California Environmental Reporting System (CERS)at http://cers.calepa.ca.gov/,and <br /> upload the required documents. <br /> This is a repeat violation, Class II. <br /> 105 CCR 2632(d)(1), 2634(d) Failed to have an approved UST monitoring plan. <br /> The monitoring plan is not current and/or not approved by the EHD. The name and number of the second person <br /> having responsibility was not listed in the monitoring plan.The monitoring plan must be uploaded to the California <br /> Environmental Reporting System (CERS). Immediately log into CERS, make the necessary changes, and submit <br /> for review by the EHD. <br /> This is a repeat violation, Class II. <br /> 107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed. <br /> An accurate UST Monitoring Site Plan was not submitted.The general pipe layout is missing. A site plan must be <br /> submitted identifying the locations where monitoring will be performed. Immediately log into the California <br /> Environmental Reporting System(CERS)at http://cers.calepa.ca.gov/and upload a copy of the UST Monitoring Site <br /> Plan. <br /> This is a repeat violation, Class II. <br /> 121 CCR 2712(f) Failed to submit a written response within 30 days of receiving an inspection report. <br /> An inspection was last done on 10/26/17 and an inspection report was issued identifying information to be submitted <br /> to bring this site into compliance. This information was required to be submitted by 11/25/18. This information was <br /> received on 3/23/18,4 months late, resulting in a non-compliant status for this facility. An operator that receives an <br /> inspection report shall have 30 days to submit a written response that includes a statement documenting corrective <br /> actions taken or proposing corrective actions which will be taken. Ensure that a written response documenting <br /> corrective actions taken or proposed is submitted within 30 days of receiving an inspection report. <br /> This is a repeat violation, Class 11. <br /> 206 CCR 2712 Failure to comply with UST operating permit conditions. <br /> A copy of the UST operating permit was not found on site. A copy of the UST operating permit and all attachments <br /> and conditions shall be retained at the facility. Immediately obtain a copy of the permit and retain it on site. <br /> This is a repeat violation, Class 11. <br /> FA0000556 PR0231841 SCO01 10/29/2018 <br /> EHD 23-01 Rev.09/28/2018 Page 4 of 6 Underground Storage Tank Program OR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sicehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.