Laserfiche WebLink
SANJ O A Q U I ` ,I�,II Environmental Health Department <br /> COUNTY <br /> Hazardous Materials Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> MANTECA CORP YARD 210 E WETMORE ST, MANTECA June 26, 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 5 HSC 25505(a)(1) Failed to complete and/or submit hazardous materials inventory for all reportable materials on site. <br /> 360 gallons of used oil were found on site that have not been reported. Any material that meets or exceeds the <br /> reportable quantity shall be reported in the facility's business plan. This violation was corrected on site. <br /> This is a minor violation. <br /> 6 HSC 25505(a)(2) Failed to complete and/or submit a site map with all required content. <br /> The site map was not complete as part of the business plan. The site map is missing a north orientation, loading <br /> areas, internal roads, adjacent streets, storm and sewer drains, access and exit points, emergency shutoffs, <br /> evacuation staging areas, hazardous material handling and storage areas, and emergency response equipment. <br /> If a site map element is not applicable for your facility then list it on the map and label as"NA". Immediately log into <br /> the California Environmental Reporting System (CERS)at http://cers.calepa.ca.gov/, upload the correct or updated <br /> information, and submit to the EHD for approval. <br /> This is a minor violation. <br /> 7 HSC 25505(a)(3) Failed to establish and/or submit emergency response procedures for a release or threatened <br /> release. <br /> The emergency response procedures were not complete. The Local Unified Program Agency(UPA)phone number <br /> was not provided on line C1. Please add 209-468-3420 as the local UPA phone number for lin C1. The evacuation <br /> staging area was not listed in section E3. Please list the evacuation meeting location in section E3. <br /> A business plan shall include the following emergency response procedures for a release or threatened release of <br /> hazardous materials, including, but not limited to,the following: <br /> -immediate notification of local emergency personnel and the Environmental Health Department(EHD) <br /> -procedures for the mitigation of a release or threatened release to minimize any potential harm or damage to <br /> persons, property, or the environment <br /> -evacuation plans and procedures, including immediate notice,for the site. <br /> This violation was corrected on site. <br /> This is a Class II violation. <br /> 9 HSC 25508(a)(1) Failed to annually review and certify that the business plan is complete, accurate, and up to date. <br /> The business plan information has not been reviewed and resubmitted in the California Environmental Reporting <br /> System (CERS)annually. The business plan was last subitted on 9/20/2018. Please make a submittal for 2019. <br /> The hazardous materials inventory shall be submitted by January 15 of each calendar year and may be submitted <br /> beginning November 1 of the previous year.This violation was corrected on site. <br /> This is a Class II violation. <br /> Overall Inspection Comments: <br /> FA0005481 PR0519882 SCO01 06/26/2019 <br /> EHD 19-01 Rev.09/27/2018 Page 2 of 3 Hazardous Materials Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />