W
<br /> Z 114 0 5 10 15 !
<br /> 1
<br /> GRAPHIC SCALE
<br /> —e.L --_-00 — -- - -- -- — --
<br /> At 00. 34' W P-6, 465,00'-- 1
<br /> /-� r< EXIST. ONGPFIE CURB -�'
<br /> 3ij � (IYP. ALONG PL.)
<br /> 10' PUBLI UTILITIES 0,� -EXISTING CHAIN-LINK FE
<br /> NrC -
<br /> - _
<br /> un
<br /> I^ FitSEb'-Nr �i I-n
<br /> l r -I wnr En�FMENi- - --- - - - _. _..-_. ---- - ��. - --- ---- -- - - - 1 to----- - - _ .11E REFER TO
<br /> 20'-p.. ROAD RIGHT-OF- �o - . _ - --._- -- - ---- - -- -- -. - -------. ._ - ----- - In
<br /> -_. - - _. I -- - -- Ixl`,• Ar `��NFILry FENCE..____� r1 2. GpfNEN51TAL'LSCOPE OF WORK" FOR ALL APPLICABLE NOTES.
<br /> N
<br /> I � ONTRACTO(i SHALL INSURE NO BEACON LOGO'S SHALL
<br /> ED ON DISPENSERS/EQUIPMENT.
<br /> I
<br /> 3. GENERAL CONTRnC TqP ;HALL PAINT NEW ISLANDS WHITE.
<br /> I EXISTING 9NSLE-STOP( BLOCK BUILDING S 00' 34' OOTrE F 165.00' I ALL DUAL-DISPENSERS TO BE REMOVED SHALL BE RETURNED
<br /> TO ULTRAMAR.
<br /> 5. ,ENERAI_ CONTRACTOR SHALT_ WORK AROUND ALL EXISTING
<br /> MONITORING & RFCOVERY LINES & WELLS. ANY LINES OR WELLS
<br /> I� I1 I DAMAGED DURING CONSTRUCTION SHALL BE REPAIRED AS REQUIRED.
<br /> 6. GENERAL CONTRACTOR IS RESPONSIBLE FOR OVERLA'r'ING 2,000 S.F.
<br /> II� WITH 1 1/2 A/C & PETROMAT AREA TO BE DETERMINED BY
<br /> IL TRAMAR ENGINES
<br /> -_ - --F-- EXIST AREA LIGHT (TYP, OF 5) EXIST. MONITORING NELI. I i
<br /> it EX15T PM NI 3) 7 GENERAL CONTRACTOR SHALL RE-USE AS MANY EXISTING CONDUITS
<br /> -.
<br /> 1}'_p" E><IS1' CONCRETE 01
<br /> AS POSSIBLE
<br /> Imo- DRIVE SLAB �- - --____-- _ OI '
<br /> R GENERAL CONTRACTOR SHALL RUN ALL NEW CONDUITS TO NEW
<br /> - I GUTTER BOX BY G C. ADJACENT TO BUILDING (SEE PLAN),
<br /> O I I REMOVE EX ST TANKS, FILL N/NEW PEA '--- - _ O
<br /> \,c - -_—_- V1
<br /> GRAVEL & PAVE ,,/ NEw 8' REINF CONT. N TIE-IN TO PDX & EXTEND C�NUUI P OVERHEAD TO EXISTING
<br /> 04 2 _
<br /> U1 I _LAB w/J(4 REBAR 4" 0,_. E.'N. ELFC:TPI( A1- PANFI /NFW EMS -GTI HAPT'T1 PANF1 IN BUILDING
<br /> N: \ �EXIST WATER VALVE \ J I
<br /> "I 4 -NEW 20,D00 GAL. DOUBLE-WALL "TRUSCO" FIBERGIAS'S a
<br /> all
<br /> 4-NEW "m s,NGLE-wA�L wSTnu CTO ACHIEVE
<br /> CONTRACTOR SHALL DEEP BUR( NEW TANKS n5 NECE`;SAI:
<br /> F.BERf,LASS VENT uNES I �UNCE RGRI ND TANKS (1- 8,000/12,000, 1-IU,G00/10,000) «/' _ I t0 ACHIEVE PROPER PIPING SLOPE FOR VAPOR RETURN
<br /> CONNEQT TO NE'N TANKS, 8' RENFGk ED CONCRETE STUD 4/b4 REBAR 024 OC. EW.
<br /> tXTEND TO RISERS k I \ REMOVE EXIST VENT RISERS N INSTALL 4-NEW 2"m GALVANIZED I ( 3
<br /> 31 CONNECT AS IREO'D.) —�, R':SERS (I-FROM EACH TANK) SLOPE 1/4" PER FT, MIN. TO TANKFi
<br /> EXTEND RISER- ABOVE ROOF LINE
<br /> l � O I GENERAL CONTRACTOR SHALL TAKE CAUTION WHEN WORKING NEAR
<br /> O I' aeMOVEI ExISfi. DIESEL �.",: ��; ' ! _ - - _ _� I EXISTING MONITORING/RECOVER'{ LINES & WELLS SO AS NOT TO
<br /> 4oI SrANOP PE ' GUARD ♦\\ -- NEW EMC/GILBARCO NI
<br /> DISTURB {HEM (ANY DAMAGE TO THESE ITEMS SHALL BE PEPAIRED
<br /> i "t', C \ L PANEL (1-rONDU1T) tt AS NECESSARY)
<br /> N � POSTS PU P IS - -- Rr G C
<br /> �' Y!/DISPNSE S - 1-- - r� - -1- �) ,
<br /> �I(I' 10,000 10000 EXISTIN(,, 2 SrOR�' BLOCK BUILDING
<br /> 0� I'
<br /> �
<br /> w - (kI 1 DIESE UNL. PWS - NEW ELECTRICAL GUTTER BOX (7UPPFr ALL
<br /> J ! � CONDUITS AS NECESSARY) CONTRACTOR MAY REUSE I - L BE RESPONSIBLE FOR REMOVAL &
<br /> EXISTIN(. CONCRETE GENERAL CONTRACTOR SHAD
<br /> w b Zlkl i �-�-� I 8,000 { by AS .MANY CONDUITS AS NECESSARY, REVIEW I GUTTER (TiPICA ) ---} - I I REPLACEMENT OF 2,000 U FC OF ASPHALT AREAS TO BE �EG€ND
<br /> o I -„44,,.1 _ IT
<br /> RUN WITH ULTRAMAR ENGINEER PRIOR I I I DETERMINED IN FIELD Bf ULTRAMAR. ENGINEER IN ADDITION i0
<br /> 1 ar - e eSUP. -e®-ON
<br /> - i^ iG NSTALvnON AREAS SHC•WN ON PLAN. U UNLEADED
<br /> b y ? I
<br /> iv ir? ob ; h f . N - EXIST. /wAI ER + UNLEADED PLD:
<br /> 12'-o--
<br /> HARING LINE l UNIT
<br /> 0 2 -0” (MIN, 20' DEPTH) EXISTI CONCRETE DRIVE SLAB I S SUPREME UNLEADED
<br /> r M �w` \ i
<br /> C w 10' 10• b� _ ° -«- — -- 3-NEW 2"0 SINGLE-WALL VR VAPC17 RETI,IRN
<br /> z < _� I Q dry -- ,-„ ,_- _ �-. FIDERGIASS PRODUCT LINES I I JiN
<br /> w L zz A ,' �SAWCUT & PATCH Stl,© I;v ,g CAU } -NEW 3/4 -� w/3 SECONDARY rONiAINMINT �rn
<br /> 0 �" y w U2 EXIST. CONC. & A/C PARE CONDUITS '0 EXIST, COLUMN - - - (TYPICAL) bµ_ y
<br /> REM VE PpRrION OF AS RETI) (TYP.) - ) 1 LJ 1...11 I a
<br /> IV (1-INTERCOM, 2-CARD READER _ .
<br /> EXIS>', CO C SLAB & TYPICAL } PLACES - 1 -NEW 3"m SINGLE-WALL
<br /> o LASS VAPOR RETURN
<br /> z x¢ REPLACE /NEW 8" - REMOVE EXIST. DIESEL_ FIBERf,.
<br /> Y w �i w pW
<br /> g J znu 3 REIN CCMC, w/k3 STANDPIPIE w/GUARD CLOPS NEW PIPING 1/4' PER FOOT J LINE (CONNECT TO EW
<br /> UNLEA.ED
<br /> x o L' "w 2M1" fO.0 E.W. I POSTS - TANK EXTEND TO NEW to fp
<br /> rw oz L MINIMUM
<br /> BACK TO TANKS (1YP.) — . MPD pt 14ANIFOLD 10 [°,� C5 I 1
<br /> z E5 z Z u s INSTALL EW 4'x12' INSTALL NEW 4'x7' RELOCATE 1-EXIST. DUAL DISPENSER r,i 0� ALL TANKS, E%CEP7 DIESEL) I �0 o N
<br /> ; O r " n �w CGNNAIFFF.���RET 15LAND CONCRETE ISLAND TYPICAL
<br /> y t0 NEW MASTER ISLAND (G.C. TO
<br /> 2 Q N 3 Ic 0 oo w/ITELOC TED DO PL DISP. w/1-SATELLITE DISP. VERIFY DISP w/ULIRAMAR) I \ I 'J
<br /> (d 1 0 1 dN� n � II - REMOVE EXIST ISLAND w/DISP. I 0�
<br /> 1-NE 2'ISW. F.G. PROD. LINE CONNECT NEW SEC. �' \ (TYPICAL OF 2) _ :r J
<br /> REMOVE EXISTING CONCRETE SLAB &
<br /> M N 000 O w/7"I SEC. CONTAINMENT (CONN. CONTAINMENT LINE FROM INSTALL NEW 8" RF.INF. CONT SUB ) LI LI ) I z'-
<br /> I �O TO N W CIESEL
<br /> TAN & EXTEND SATEI-LITE LINE Il) MAN � --NEW 4'x7' CONCRETE DOG80NE
<br /> ¢ I O P w z w 3 0 24" O.C. EACH WAY
<br /> 'rro , eu a: rt TO NFw M jIER/SATELLITE DISP - LINE SECONDARY /'� ISLAND w/1-MPD
<br /> 'JONTAINMENt EXIST. CANOPY COLUMN TO REMAIN _
<br /> RIGHT-OF WAY EASEMENT
<br /> PROTECT IN ---
<br /> [ ] PA ) tt
<br /> CEP. Of 2 l (AP LOCATION)
<br /> J � �
<br /> —�-EXIS GONG_SLAB -- _ _ ' ,
<br /> ---_ ° - - - �- EXISTING PLANTER
<br /> F-00. 34' 0 E P.L. 250.00 —
<br /> I
<br /> CONT. APPROn/'H 'i EXISTING CONCRETE SIDEWALK 11 EXIST. CON(„ EXISIING CONCRETE SIDEWALI' EXISI CONC. APPROACH II Ix ST GONE SIDEWALK
<br /> _ ____ EXIST E L. T
<br /> EXIST ('DNC SIDEWAL �� APPROACH
<br /> _ _.._._-_ - GUTTER
<br /> E%I;tING SONCItE TE Cl1RD &
<br /> MPD MPD
<br /> 4' 3'-G 3-=6' -� 3'-6'
<br /> ISL COL.
<br /> ISL OF FIRST FILL
<br /> NEW TANK LAYOUT DIMENSION NEW NEW
<br /> (VERIFY w/ULTRAMAR ENGINEER) ISLAND ISLAND
<br /> C H E R O K E E L A N E
<br /> APPROVED
<br /> DRAWING ISSUED FOR DATE A&S ULTRMR REVISIONS
<br /> mawULIRAMAR ENGINEER NO. DATE BY COMMENTS
<br /> 1 110 29 93 JLH REVISED ISUNDS PIPNG PER ULTRAMAR. ____
<br /> 2 111Z2/93 TJLH11VIlff ISLANDS PIPING NOTES PER ULTRAMAR. 525 'WEST THIRD STREET, HANFORD, CALIFORNIA 93230
<br /> STEEL FABRICATOR NAME:_--___-__PIANNINC - - PROPOSED PLOT PLAN -
<br /> PERMIT PLANS PREPARED BY: 900 S. CHEROKEE LANE
<br /> M BID CONTRACT DOCUMENT A & S BNQINBBRING LODI, CALIFORNIA
<br /> CONTRACTOR TO CONTACT NOT FOR CONSTRUCTION —
<br /> UNDERGROUND SERVICE ALERT CONSTRUCTION PLANNING ENGINEERING CONSTRUCTION MANAGEMENT SCALE: I "=20'—O" S.S. 695
<br /> 1 -800-422-4133 DO NOT USE FOR CONST.
<br /> O UNLESS BOTH SIG. APE IN NAND 207 WEST ALAMEDA AVENUE SUITE 202 DATE: 1027/9.3
<br /> w FOR CALLUNDERGROUNDSOCATINC BURBANK. CALIFORNIA 91502 OWN. BY: J.L.HE-RBS( DRAWING S- i
<br /> Y RECORD DRAWING PHONE: 818-842-3644 FAX 818-842-3760
<br /> O 2 WORKING DAYS BEFORE YOU DIG CHKD. BY: SHEET 2 OF 7
<br /> j w
<br /> ! x
<br /> U
<br /> a'
<br />
|