Stockton Plating <br /> B&OW <br /> v— <br /> b work Pian <br /> November 17, 1993 <br />' Page - 4 - <br />' encountered at depth of approximately 25 feet below the ground <br /> surface to the capillary fringe at 50 feet. Information <br /> regarding the investigation summarized above was reported by <br /> Condor (Prelsmsnary Investigation and Evaluation Report, October <br /> 10, 1991) . <br /> 3.0 PROPOSED SCOPE OF WORK <br /> The work proposed for this investigation includes drilling, <br /> installation and sampling of three ( 3) monitor wells at the SPI <br /> site (Appendix A, Figure 2 , Proposed Monitor Well Locations) . <br /> The wells will be placed in a triangular pattern around the <br /> former location of the tanks to investigate the vertical and <br /> lateral extent of soil and possible groundwater contamination and <br /> to determine the groundwater gradient. A Health and Safety Plan <br /> has been prepared and is included with this work plan (Appendix <br /> B) . Monitor well permits will be obtained from San Joaquin <br /> County prior to drilling. The field and laboratory work proposed <br /> for this investigation are outlined in detail below. <br /> 3.1 Drilling and Soil Sampling <br /> The monitor wells will be drilled by Spectrum Exploration, <br /> Inc . , of Stockton, California, (C57 license #512268) , under the <br /> supervision of a Condor geologist. The Underground Service Alert <br /> f (USA) will be notified at least 48 hours prior to drilling <br />• operations. The wells will be drilled using 10 to 12-inch O.D. <br /> Ntiw- <br /> 4,8 CONDOR <br />